CEBORA S.p.A
10.3 Insulated Voltage Analog Output wiring.
10.3.1 Features.
output voltage
output current
output frequency
10.4 V_Arc-ISO.
CNC connector terminals
on Power Source
11
7
"V_Arc-ISO" is the signal related to the Power Source output arc voltage ("electrode-workpiece"
voltage), supplied in isolated and reduced mode.
"V_Arc-ISO" signal is available with the following full scale values:
voltage from 0 to 5V, corresponding to arc voltage from 0 to 250V (reduction ratio = 1/50);
voltage from 0 to 10V, corresponding to arc voltage from 0 to 250V (reduction ratio = 1/25).
The full scale value depends up on the SW2 dip-
switches position, on the Remote board (see fig.
11.3), in compliance with the table a side.
NOTE: Both sections 1 and 2 of SW2 must always be in the same positions (ex.: both ON or both OFF).
The V_Arc-ISO signal availability depends up on the
SW3 dip-switches position, on the Remote board (see
fig. 11.3), in compliance with the table a side.
NOTE: The Remote board is supplied from factory
with the arc voltage output set in V_Arc-NO-
ISO mode.
3.300.232-B
0 ÷ 10 Vdc, max;
20 mA, max.;
5 Hz, max.
Signal name
V_Arc-ISO
(0 ÷ 5 V) (0 ÷ 10 V)
Position on Remote
Signal type
Analog out +
Analog out -
Full scale value for
V_Arc-ISO signal
10V
5V
Dip Switches
SW3
signal availability
1
2
Not Connected
3
4
Not Connected
5
6
Not Connected
7
8
15
board
J2, pin 6
J2, pin 8
GB
SW2
SW2
1
2
OFF
OFF
ON
ON
V_Arc-ISO
OFF
OFF
ON
ON
ON
04/03/2016