vitra. CDS Manual De Instrucciones página 26

Ocultar thumbs Ver también para CDS:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Troubleshooting
EN
Display
E61
E62
E63
E64
E65
E67
E70
E71
E81
E93
An error cannot be resolved as described: pull out the power adapter plug, wait a few minutes and try to reinitialise the table (RESET).
If the error then reoccurs, disconnect the table from the mains power and contact your Vitra retail partner.
26
Cause
Motor exchanged
Overcurrent
External sensor or cable
not connected
Authentication error
Overcurrent or short circuit
Overvoltage
Change to the drive
configuration
Sensor – configuration
changed
Internal error
Connection error in cascaded
group.
Error is displayed for 15
seconds. After this, the control
system changes over to the
reset mode.
Solution
Connection to motor has been broken or a new motor has been connected. Reinitialise table
(RESET)
Complete overcurrent of control system due to overload
External anti-squeeze bar or other accessory module not connected, if necessary check
plug connector
Reinitialise table (RESET)
If an error occurs during movement. Collision? Excessive load?
Unplug power adapter! Contact your Vitra retail partner.
Unplug power adapter from mains and wait at least 5 seconds, then reinitialise the table
(RESET)
An (optional) attached sensor has been removed or the connection has been lost.
Observe the special instructions for the sensor!
Memory or initialisation error, reinitialise the table (RESET)
Check connection and reinitialise (RESET) the table

Publicidad

Tabla de contenido
loading

Tabla de contenido