GB
The handles are equipped with vibration
dampers to improve working safety and
reduce wrist and arm joint fatigue.
You can vacuum up dry leaves and leaf
parts on the flat with the flat suction noz-
zle. The guide rollers at the lower end of
the tube make it easier to guide the tube
along the ground.To protect the user,
the appliance can only be used with
the blowing/suction pipe completely
installed. The appliance is double-insu-
lated, and does not need to be earthed.
Refer to the following descriptions for in-
structions on how the operating controls
work.
Technical Data
Foliage vacuum ...............DG-ELB 3014
Rated input voltage ...... 230-240 V~, 50 Hz
Idling speed ..................6000-15000 min
Input power .................................. 3000 W
Safety class ........................................
Air capacity ...................... max. 14 m
Air speed ....................max. 140-270 km/h
Shredding rate ................................... 10:1
Content of the collection bag ..............40 l
Weight .......................................ca. 3.2 kg
Sound pressure level
(L
) ........................ 86 dB(A); K
pA
Sound power level (L
measured ............. 96.0 dB(A); K
guaranteed ..............................99 dB(A)
Vibration (a
) ............. 4.5 m/s
h
Noise and Vibration: Noise and vibration
values were determined according to the
standards and stipulations designated in
the Declaration of Conformity. The oper-
ating conditions during measuring and
the procedures used for measuring in
accordance with EN 15503, Appendix A,
Appendix B.
22
/min
3
= 3 dB
pA
)
WA
=3 dB
WA
; K=1.5 m/s
2
• Warning! During operation, this elec-
tric tool generates an electromagnetic
field which, under certain circum-
stances, may impair the functionality
of active or passive medical implants.
To reduce the risk of serious or lethal
injuries, we recommend that persons
with medical implants consult their
doctor and the manufacturer of their
medical implant before operating the
machine.
Technical and optical changes can be
carried out in the course of the further
development without announcement. All
measures, references and information
contained in this operating manual are
therefore without guarantee. Legal claims,
which are made on the basis of the oper-
ating manual, cannot be considered.
-1
This device is designed for operation on
II
a power supply network with a system
impedance Zmax at the transfer point
(domestic connection) of a maximum of
0.28 Ohms. The user must ensure that the
device is operated only on a power supply
network that fulfils this requirement. If nec-
essary, the local power supply company
can be asked for the system impedance.
Notes on safety
This section deals with the basic
2
safety regulations to be observed
when working with the machine.
Symbols on the device
Caution, danger !
Read through the operating
manual carefully before us-
ing the device.