Trouble Shooting; Fault Correction - Deltafox DG-ELB 3014 Traducción Del Manual De Instrucciones Original

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 78

Trouble shooting

Problem
Device does not
start
Device works with
interruptions
Low suction ca-
pacity or suction
not present
Small or missing
blowing power
Device works with
interruptions
Possible cause
Mains voltage is not present
Defective on/off switch (8)
Worn carbon brushes
Defective motor
Blowing/suction pipe
(2a+2b) is not completely
fitted
Damaged power cable
Internal loose connection
Defective on/off switch (8)
Collection bag (16) is full
Collection bag (16) is dirty
Selector switch (14) in
incorrect position
Device clogged up or
blocked by foreign bodies
Selector switch (14) in incor-
rect position
Airstream regulator (7) in
incorrect position
Foreign body blocks
impeller wheel

Fault correction

Check plug socket, cable, line, plug
and fuse, where appropriate, repair
through electrical specialist
Repair through customer service
Install a two-part blowing/suction
pipe (2a+2b)
Check cable; where appropriate,
replace
Repair through customer service
Empty collection bag (16)
Clean collection bag (16)
Set selector switch (14) to the
suction symbol
Remove plug or blockages (see
"Cleaning and Maintenance")
Set selector switch (14) to the
blowing symbol
Rotate airstream regulator (7) to high
position
Remove blockage (see chapter
Cleaning and Maintenance)
GB
33

Publicidad

Tabla de contenido
loading

Tabla de contenido