Pressure Regulator Conversion; Converting Appliances For Use With Ng Gas - Verona VECTGV304SS Manual De Instalación

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Converting Appliances for Use with NG
Gas
If this appliance should be converted for use with gas
NG (natural gas), each of the following modifications
must be performed.
1. Replace all injectors following the step described
on page 18, observe the number stamped on the
side, this number codes the orifice diameter and
its correct burner location (following the illustration
of injectors position).
2. Convert the pressure regulator on LP position (fol-
lowing the illustration of pressure regulator con-
version).
3. Adjust the burner flame (see Low Flame Adjust-
ment paragraph).
Check the appearance of each burner's flame at HI-
LO settings, if the flame appears too large or too small
make sure that all steps were completed correctly.

Pressure regulator conversion

The appliances is designed for use with NG gas or LP
gas. The gas pressure regulator is supplied. It must
be installed in the gas way ahead of manifold en-
trance. It is pre-set for use with the gas supplied with
the appliances. For use with different gas must be
converted.
For the pressure regulator conversion following
the below instructions:
x
Disconnect all electrical power, at the main circuit
breaker or fuse box.
x
Shut off the gas supply to the cooktop by closing
the manual shut-off valve.
x
Adjust the pressure regulator, by following the in-
struction (see figure)
1. Unscrew the regulator cap
2. Unscrew the plastic conversion plug from the cap
turn over and screw back (wide section away from
cap for LP and against cap for NG) see figures
below.
3. Replace the cap regulator.
Before replace the regulator cap.
Check the position of plug.
Suitable for the gas converted.
Figure 20. Pressure regulator conversion
Installation Manual
ENGLISH
17

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Vectgv365ss