WHEN USING THE STANDARD BALL/DOWNROD
MOUNTING, THE TAB IN THE RING AT THE
BOTTOM OF THE MOUNTING PLATE MUST
REST IN THE GROOVE OF THE HANGER BALL.
FAILURE TO PROPERLY SEAT THE TAB IN THE
GROOVE COULD CAUSE DAMAGE TO WIRING.
Installing Fan to
the Outlet Box
WHEN MOUNTING THE FAN ON A SLOPED
CEILING, THE STANDARD BALL/DOWNROD
MOUNTING METHOD MUST BE USED. MAKE
SURE THE MOUNTING PLATE SLOTS ARE ON
THE LOWER SIDE BY SLIDING THE MOUNTING
BRACKET FROM THE TOP DOWN.
1. Pass the 120-volt supply wires through the
center hole in the ceiling mounting plate as
shown in Figure 7.
2. Install the ceiling mounting plate on the out-
let box by sliding the mounting plate over
the two screws provided with the outlet box.
When using close-to-ceiling mounting, it is
important that the mounting plate be level. If
necessary, use leveling washers (not includ-
ed) between the mounting plate and the out-
let box. Note that the flat side of the mount-
ing plate is toward the outlet box (Figure 7).
3. Securely tighten the two mounting screws.
4. Carefully lift the assembly up to the ceil-
ing mounting plate. If using Close-to-
Ceiling mounting, hang the fan on the
6.
hook provided by utilizing one of the
holes at the outer rim of the ceiling canopy
(Figure 12). If using standard mounting,
seat the hanger ball in the mounting plate
socket. Make sure the tab on the mounting
plate socket is properly seated in the groove
in the hanger ball (Figure 12).
THE HOOK AS SHOWN IN FIGURE 12 IS ONLY
TO BALANCE FAN WHILE ATTACHING WIRING.
FAILURE TO HANG AS SHOWN IN FIGURE 12
MAY RESULT IN HOOK BREAKING, CAUSING
THE FAN TO FALL. HOOK MUST PASS FROM
INSIDE TO OUTSIDE OF CANOPY.
Making the Electrical
Connections
REMEMBER to disconnect the power. If
you feel you do not have enough electrical
wiring knowledge or experience, have your fan
installed by a licensed electrician.
Follow the steps below to connect the fan
to your household wiring. Use the wire
connecting nuts supplied with your fan. Se-
cure the connectors with electrical tape.
Make sure there are no loose strands or
connections.
1. Connect the two green fan ground wires lo-
cated on the downrod and mounting plate
to the household ground wire. When using
Close-to-Ceiling mounting, there is only one
green ground wire from the ceiling mount-
ing plate since the ball/downrod assembly is
not used.
ELECTRICAL DIAGRAMS ARE FOR REFERENCE
ONLY. OPTIONAL USE OF ANY LIGHT KIT SHALL
BE UL LISTED AND MARKED SUITABLE FOR
USE WITH THIS FAN.
Figure 12
2. IF USING OPTIONAL LIGHT KIT, Con-
nect the fan light supply (blue) wire and the
fan supply (black) wire to the black house-
hold supply wire as shown in figure 13.
USE ONLY WITH LIGHT KITS MARKED "SUIT-
ABLE FOR USE IN DAMP LOCATION".
3. Connect the neutral fan (white) wire to the
white neutral household wire.
4. After connecting the wires, spread them
apart so that the green and white wires are
on side of the outlet box and the black wire
is on the other side.