- Input impedance: 10M
- Max. input voltage: 600V DC or AC True-RMS.
- Frequency reponse: 40~400Hz
- Response: True-RMS
3.2.3 Resistance
400Ω
4KΩ
40KΩ
400KΩ
4MΩ
40MΩ
- Overload protection: 600 DC or AC True-RMS
3.2.4 Diode test
2.7V
1mV
- Overload protection: 600V DC or AC True-RMS
3.2.5 Continuity
Open circuit
voltage~1 V
- Overload protection: 600V DC or AC True-RMS
±( 0.8% of reading + 3 digits )
Displays shows forward
voltage drop
11
3.2.6 DC current
400μA
4000μA
±( 1.0% of reading + 10 digits )
40mA
0.01mA
400mA
0.1mA
10A
- Overload protection:
mA jack: FF 400mA H 1000V
10A jack: FF 10A H 600V
- Max input current:
mA jack: 400mA
10A jack: 10A
3.2.7 AC current
400μA
4000μA
±( 1.5% of reading + 5 digits )
40mA
0.01mA
400mA
0.1mA
10A
±( 3.0% of reading + 5 digits )
- Overload protection:
mA jack: FF 400mA H 1000V
10A jack: FF 10A H 600V
- Frequency response: 40~400Hz, true RMS response
- Max input current: mA jack: 400mA DC or AC rms
10A jack: 10A DC or AC rms
- When measuring current exceeding 2A, do not measure
for longer than 2 minutes continuously. Wait 10 minutes
to continue measurement.
12