DESCRIPTION
Closing after transit
During the automatic operation, the pause count down starts from the set
up value each time a photocell operates during the pause.
If the photocell operates during the opening time, this time will be
immediately stored as pause time.
This function allows having a fast closing after the transit through the
barrier, for which usually a lesser time for
used.
Function deactivated
The barrier recloses after the time set
Pause after the transit
In order to render minimum the time in which the barrier remains open,
it is possible to make the barrier close as soon as the passage in front of
photocells has ended. If the automatic operation is enabled, the
value is loaded/programmed as time of pause
Function deactivated
Courtesy lights
This menu allows setting up the operation of the courtesy lights
automatically during the barrier's opening cycle.
Timed functioning (from 0 to 20')
Function disabled
Turned on for the entire duration of the cycle
Auxiliary channel
This menu allows setting the operating of the relay of the lighting of the
courtesy lights by means of a remote control stored on the channel 4 of
the receiver MR
Timed functioning (from 0 a 20')
Bistable functioning
Monostable functioning
Setting low voltage light output
Flashing function (fixed frequency)
Function disabled
Spy lamp function: it indicates in real time the state of the barrier, the type
of flash indicates the four possible conditions:
- BARRIER CLOSED the light is off
- BARRIER IN PAUSE the light is on fixed
PLEASE NOTE: the light remains off if the ENERGY SAVING function is
enabled and automatic closure is deactivated
- BARRIER IN OPENING the light blinks slowly (2Hz)
- BARRIER IN CLOSING the light blinks fast (4Hz)
Flashing lamp in pause
Function disabled
The flashing lamp works also during the pause time (barrier opened with
active automatic closing).
Ch.AU
(automatic closing) is
- 57 -
DEFAULT
MEMO
no
no
Ch.tr
t.LUC
1 '00
Mon
FLSh
no