Technical Data
Solder fume extraction
Dimensions L x W x H
Weight
Max. extraction capacity
Compressor performance
Rated power consumption
Rated voltage
Glass tube fuse (5 x 20)
Operating sound level from 1 m distance
Combined filter
Interface
Operation
Note
The unit may emit dust from the main filter
after transportation. Make sure that the unit is
put into service in a suitable room.
Caution!
A high noxious gas concentration will
cause the activated charcoal to heat up.
To avoid overheating, the unit should be
run without noxious gases for several
minutes before switching off.
PK Elektronik Vertriebs GmbH, E-Mail: info@pkelektronik.com, Internet: www.pkelektronik.com
MG100S
460 x 210 x 640 mm
18.1 x 8.3 x 25.2 inch
15 kg
100 m³/ h (58,8 CFM)
140 m
/ h (82,3 CFM)
3
100 W
110-240 V / 50/60 Hz
2 x 6,3 AT, 250 V
< 52 dB(A)
Combined E12 high
efficiency submicron filter
(99.95 % particle separati-
on upto 0.12 μm) and wide
band gas filter
(50 % activated carbon, 50
% Puratex)
The full range of system functions can be operated and
remotely monitored via the interface using an optional
interface adaptor.
Put the tool into operation as described in the
chapter „Placing into operation".
Please adhere to the operating instructions of the
connected devices.
Check to see if the mains voltage matches the
ratings on the nameplate.
Make sure the machine is switched off before
plugging in.
Optimal gas filtration is achieved as follows:
• Temperature of process air in gas filter < 38 °C
• Relative humidity < 60 %
• Gas molecules > 30 g/mol (better filtration
results are achieved with larger molecules)
• Boiling point of the gas molecules > 0 °C
MP140
420 x 200 x 440 mm
16.5 x 7.8 x 17.3 inch
8 kg
100 m³/ h (58,8 CFM)
140 m
/ h (82,3 CFM)
3
100 W
110-240 V / 50/60 Hz
2 x 6,3 AT, 250 V
< 54 dB(A)
Combined E12 high
efficiency submicron filter
(99.95 % particle separati-
on upto 0.12 μm).
15