Care and maintenance

Filter change

Warning!
Before doing any work on the
machine, pull the plug out of the
socket.
Warning!
Use original replacement parts only.
The unit must not be altered or modi-
fied in any way!
Repairs must always be referred to a
Weller-trained specialist.
The normal service life of a main
MIN 1x
filter in the electronics industry is
1500 hours.
The main filter should be chan-
ged at least once a year in order
year
to ensure proper gas separation.
Cleaning
To ensure that the unit functions properly, the nozzle, extractor arm and connecting hose must be clea-
ned on a regular basis.

Error messages and error clearance

Message/symptom
Extraction power missing
Loud extraction noises
Unit is not running
Device does not work
16
PK Elektronik Vertriebs GmbH, E-Mail: info@pkelektronik.com, Internet: www.pkelektronik.com
An alarm sounds and the red warning light
flashes:
Recommended service life of filter has expired.
Indicates that the filter needs changing. Reset the
alarm with the reset function on the control panel
and schedule a filter change.
An alarm sounds and the red warning light is
lit continuously:
Extraction capacity is too low.
Switch off the filter unit. Check the nozzles and
tubes, and clean them if necessary. If the alarm
sounds again the next time the unit is turned on,
the filter must be changed.
If no action is taken, the filter unit will cut out after
five minutes in order to avoid overheating.
When changing the main filter the filtration time
can be reset as follows:
Keep the reset button pressed and, at the same
time, turn on the switch until a signal sounds.
Possible cause
Pipe system leaking
Filter is dirty
Turbine speed too low
Air speed through extraction-
arm is too high speed
Thermally switched off
Fuse is blown
Unit is not properly connected
Remedial measures
Reseal the pipe system
change the filter
Increase the speed setting
only MG100S
Reduce the air speed (reduce air
quanitity) only MG100S
Leave the unit to cool down.
Switch on again after approx.
3 hours.
Please contact our Customer
Service:
technical-service@weller-tools.com
Check the electrical connections