Turning on the Appliance
 Set appliance switch to desired operating mode.
Indicator lamp for operational readiness lights up.
The device starts briefly and turns off, as soon as the
working pressure is reached.
Note: If the indicator lamps for pump, lack of water, boil-
er malfunction or motor, turn off the appliance immedi-
ately and repair malfunction, refer to "Help with malfunc-
tions".
 Release the trigger gun. To do so, push the safety
catch towards the back.
When activating the hand spray gun the device switch-
es back on.
Note: If no water comes out of the high pressure nozzle,
vent pump. Refer to "Help with malfunctions - appliance
is not building up pressure".
Adjust cleaning temperature
 Set temperature regulator to desired temperature.
86 °F/30 °C to 185 °F/85 °C:
Clean with hot water.
Set working pressure and flow rate
Pressure/quantity regulation of the pump unit
 Turn the regulation spindle in a clockwise direction:
Increase working pressure (MAX).
 Turn the regulation spindle in an anti-clockwise di-
rection: Reduce working pressure (MIN).
Operation with detergent
For considerate treatment of the environment use
detergent economically.
The detergent must be suitable for the surface to
be cleaned.
 With support of the detergent dose valve set deter-
gent concentration as determined by the manufac-
turer.
Note: Recommended values at the control panel at
maximum working pressure.
 Set pressure/temperature and detergent concen-
tration according to the surface to be cleaned.
Note: To prevent damage due to too much pressure, al-
ways position high pressure ray first from a greater dis-
tance towards object to be cleaned.
Recommended cleaning method
Loosen the dirt:
 Spray detergent economically and let it work for
1...5 minutes but do not let it dry up.
Remove the dirt:
 Spray off loosened dirt with the high pressure jet.
Operating with cold water
Removal of light contaminations and clear rinse, i.e.:
Gardening tools, terrace, tools, etc.
 Set operating pressure according to need.
Eco! efficiency setting
The appliance works in the most economical tempera-
ture range.
Note: The temperature can be regulated up to 140 °F/
60 °C.
10
Cleaning
Operating with hot water
We recommend the following cleaning temperatures:
Light contaminations
86 °F/30 °C-122 °F/50 °C
Contaminations containing protein, i.e. in the food
processing industry
max. 140 °F/60 °C
Vehicle cleaning, machine cleaning
140 °F/60 °C-185 °F/85 °C
DANGER
Scalding danger!
 Set temperature regulator to desired temperature.
Note: Changing the working pressure and the feed vol-
ume will also change the water temperature.

Interrupting operation

 Secure the trigger gun. To do so, push the safety
catch towards the front.
After operation with detergent
 Set dosing value for detergent to "0".
 Set the appliance switch to "1" (operation with cold
water).
 Open the hand spray gun and rinse the appliance
for at least 1 minute.
Turn off the appliance
DANGER
Danger of scalding by hot water. After operation with hot
water, the appliance must be operated with an open gun
with cold water for at least five minutes to cool it off.
 Shut off water supply.
 Open the hand spray gun.
 Switch on the pump with the power switch and al-
low to run for about 5-10 seconds.
 Close the hand spray gun.
 Set the appliance switch to "0/OFF".
 Pull main plug out of socket with dry hands only.
 Remove water connection.
 Activate hand spray gun until device is pressure
less.
 Secure the trigger gun. To do so, push the safety
catch towards the front.
Storing the Appliance
 Lock in the steel pipe into the holder of the appli-
ance hood.
 Roll up high pressure hose and electrical conduit
and hang them into the respective holders.
Note: Do not twist high pressure hose and electrical
conduit.
ATTENTION
Risk of damage! Frost will destroy the appliance if the
water has not been completely drained.
 Store in a frost free area.
If it is not possible to store frost free, shut down device.
For longer work breaks or if a frost free storage is not
possible:
 Empty detergent tank.
 Drain water.
 Flush device with anti-freeze agent.