Dump water
Screw off water supply hose and high pressure
hose.
Unscrew the drain screw of the boiler on the bottom
of the boiler and empty the boiler.
Operate device for max. 1 minute until the pump
and conduits are empty.
Flush device with anti-freeze agent
Note: Observe handling instructions of the anti-freeze
agent manufacturer.
Fill commercial grade anti-freeze into the boiler.
Switch on appliance (without heater) until the appli-
ance has been completely rinsed.
A certain corrosion protection is achieved with this as
well.
Storage
CAUTION
Risk of personal injury or damage! Consider the weight
of the appliance when storing it.
Transport
Figure 6
ATTENTION
Risk of damage! When loading the appliance with a
forklift, observe the illustration.
ATTENTION
Protect the trigger from damage during transport.
CAUTION
Risk of personal injury or damage! Mind the weight of
the appliance during transport.
When transporting in vehicles, secure the appli-
ance according to the guidelines from slipping and
tipping over.
Care and maintenance
DANGER
Risk of injury by inadvertent start-up of appliance and
electric shock. Prior to all work on the appliance, switch
off the appliance and pull the power plug.
Shut off water supply.
Open the hand spray gun.
Switch on the pump with the power switch and al-
low to run for about 5-10 seconds.
Close the hand spray gun.
Set the appliance switch to "0/OFF".
Pull main plug out of socket with dry hands only.
Remove water connection.
Activate hand spray gun until device is pressure
less.
Secure the trigger gun. To do so, push the safety
catch towards the front.
Allow device to cool down.
Your Kärcher vender will inform you about the per-
formance of a periodic safety inspection resp. sign-
ing of a maintenance contract.
Maintenance intervals
Weekly
Clean the sieve in the water connection.
Clean the fine filter.
Check oil level.
ATTENTION
Risk of damage! In case of lacteous oil inform Kärcher
customer service immediately.
Monthly
Clean the sieve in the safety block.
Clean filter at the detergent suck hose.
After 400 operating hours, at least annually
Check the calcification degree of the boiler and
consider having it cleaned by customer service.
Every 500 operating hours, at least annually
Oil change.
Have the maintenance of the device performed by
the customer service.
Maintenance Works
Clean the sieve in the water connection
Take out sieve.
Clean sieve in water and reinstall.
Cleaning the fine filter
Unpressurize the appliance.
Unscrew the fine filter from the boiler.
Remove the fine filter and the filter insert.
Clean the filter with clean water or compressed air.
Reinstall in reverse sequence.
Clean the sieve in the safety block
Unpressurize the appliance.
Loosen covering nut and take off hose.
Take out sieve.
Note: If necessary turn in screw M8 appr. 0.2 in/5 mm
inwards and therewith pull out sieve.
Clean sieve in water.
Push sieve inwards.
Put on hose.
Tighten covering nut firmly.
Clean filter at the detergent suck hose
Take out detergent suck supports.
Clean filter in water and reinstall.
Oil change
Ready a catch bin for appr. 0.26 gal/1 Liter oil.
Loosen release screw.
Dispose of old oil ecologically or turn in at a gathering
point.
Tighten release screw.
Fill oil slowly up to the MAX marking.
Note: Air pockets must be able to leak out.
For oil type refer to technical specifications.
Troubleshooting
DANGER
Risk of injury by inadvertent start-up of appliance and
electric shock. Prior to all work on the appliance, switch
off the appliance and pull the power plug.
Indicator lamp pump
2x blinking
–
Leak in the high pressure system
Check high pressure system and connections for
tightness.
3x blinking
–
Lack of water after 2 minutes - the pump is
switched off to prevent dry runs.
Check water supply, check connections.
– 5
EN
11