3.2 – FLOW CHART
3.3 – ELECTRIC DRAWING AND CONTROL PANEL
REP. DESCRIPTION
40
Electric box
41
Red selector switch
42
Blue selector switch
43
Blue selector switch
44
Green selector switch
45
Connector 4P
46
Hour meter
47
Connector 8P
48
Transformer
49
Circuit breaker
50
Circuit breaker
51
Salinometer card
52
Fuse
53
Contactor
54
Contactor
See the control panel in ANNEXES page 56.
See the electric drawing in ANNEXES page 54 AND the electric connections page 55.
\\Serveurslce3\dao\Etude-3d\Aquaset\0-DOSSIER TECHNIQUES\1-sw-plaisance\AQUA-BASE YK\09-Manuel utilisateur\AQUABASE YK FRUKES 2018-02-O.doc
FUNCTION
Stopping of the unit.
Automatic flushing system (option).
Sand-filter cleaning (option).
Starting up of the unit and indication with an integrated signal lamp.
Insures connection of automatic flushing system.
Indicates the running time of the unit.
Insures connection of the remote panel
Supply of 24VAC current to the control box.
Protection of the HP pump electric motor, in case of overload.
Protection of the booster pump electric motor, in case of overload.
Measures the salinity of the produced water with a cell ; shows the measure with the LED
indicator (green, red). Shows the functioning of the unit with LED : ON – OFF RINSING.
Protection of the electric box.
Feeds the booster pump electric motor.
Feeds the HP pump electric motor.
FR/UK/ES Page 20/66
VERSION 2018-02-O