The AQUA-BASE unit must be regularly maintained in order to avoid the occurrence of defects, which could affect its efficiency, its
operation and its reliability. The intervals between maintenance of the AQUA-BASE unit depend on the frequency and conditions of use.
1 – MAINTENANCE SCHEDULE
OPERATION
Replacement of filter cartridges
Checking oil level
Oil change
Cleaning the prime filter
Cleaning the cell
Cleaning the membrane(s)
Replacement of mechanical seals
Replacement carbone actif filter (extra)
On this basis the user will adapt his own maintenance schedule, which will depend on his personal use of the unit.
2 – SPARE PARTS FOR ONE YEAR
The spare parts set, for one year
servicing the AQUA-BASE watermaker unit (without option):
QTY
REFERENCE
4
711058
4
711014
1
752038
2
752002-20
1
752037-EXP10
3 – REPLACEMENT OF THE FILTER CARTRIDGE (Unit stopped)
1.
Stop the unit by pressing OFF (41).
2.
Close the hull valve (V0).
3.
Open the filter by unscrewing the tightening nut using the filter spanner.
4.
Free the used cartridges by setting down the filter bowl.
5.
Replace the used cartridges with a genuine new one (see colours).
6.
Wipe and lightly oil the seal with food fat.
7.
Reset the filter after having checked the cartridge position.
8.
Screw the tightening nut by hand.
Don't reverse the cartridges 20µ and 5µ.
(The center of the cartridge 20µ is of red or pink color, that of 5µ is of green color)
YC5 filter: The bowl filter is designed for 10" cartridge, on the market 9" 3/4 (U.S. standard) exist but the filtration
becomes insufficient to protect osmosis membrane. In the case of using this type of cartridge with or without foam
seal to compensate for the height difference, SLCE disclaims any liability on the dirt and the life of the membranes.
If the user wishes to use this standard cartridge, it must replace the filters 10" by a model compatible cartridges
9"3/4.
\\Serveurslce3\dao\Etude-3d\Aquaset\0-DOSSIER TECHNIQUES\1-sw-plaisance\AQUA-BASE YK\09-Manuel utilisateur\AQUABASE YK FRUKES 2018-02-O.doc
D – WATERMAKER MAINTENANCE
FREQUENCY
When it is clogged and at wintering
Every week when used regularly
Every year
When it is clogged
Every year
Each year at wintering
Every year
Every year
AQUA-BASE
, Ref. 752047 (YK1 to 4) or Ref. 752048 (YK5), contains all the necessary parts for
752047 (YK1 to 4)
DESCRIPTION
Filter element 20µ-7"
Filter element 5µ-7"
HP pump oil (0.5 liter)
Storage solution
Cleaner kit A+B
Minimum
1 / year
1 / week
1 / year
1 / week
1 / year
1 / year
1 / year or
2500H
1 / year
752048 (YK5)
REFERENCE
DESCRIPTION
711007
Filter element 20µ-10"
711019
Filter element 5µ-10"
752001
HP pump oil (1 liter)
752002-20
Storage solution
752037-EXP10
Cleaner kit A+B
NECESSARY SPARE PARTS
711014 and 711058 : YK1 to 4
711007 and 711019 : YK5
752038 : YK1 to 4
752001 : YK5
752037-EXP10
See annexes (different types)
712029
FR/UK/ES Page 28/66
VERSION 2018-02-O