Electrical Connection; Cleaning, Maintenance And Storage - Scheppach Air Force Traducción Del Manual De Instrucciones Original

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 154
To do so, please first remove the hose with the valve
adapter (8).
Now screw the blow-out adapter (D) to the tyre infla-
tion device (G).
Using the adapter set
The adapter set enables you to use the following ad-
ditional capabilities of the tyre inflation device:
• Pumping up balls with the help of the ball needle
(F).
• The valve adapter (E) enables bicycle tyres to be
inflated.
• Filling pools, air mattresses or boats with the help
of the additional adapter (K).
• Filling items with threaded valves (e.g. Boats) with
the screw-in valve adapter (J).
• Deflating large volume items. The deflating adapter
(C) can be used for this.
• The two conical universal adapters (A/B) can like-
wise be used for inflating air mattresses.

9. Electrical connection

The electrical motor installed is connected and
ready for operation. The connection complies
with the applicable VDE and DIN provisions.
The customer's mains connection as well as
the extension cable used must also comply with
these regulations.
Damaged electrical connection cable
The insulation on electrical connection cables is of-
ten damaged.
This may have the following causes:
• Passage points, where connection cables are
passed through windows or doors.
• Kinks where the connection cable has been im-
properly fastened or routed.
• Places where the connection cables have been cut
due to being driven over.
• Insulation damage due to being ripped out of the
wall outlet.
• Cracks due to the insulation ageing.
Such damaged electrical connection cables must not
be used and are life-threatening due to the insula-
tion damage.
Check the electrical connection cables for damage
regularly. Make sure that the connection cable does
not hang on the power network during the inspection.
Electrical connection cables must comply with the
applicable VDE and DIN provisions. Only use con-
nection cables with the marking „H05VV-F".
The printing of the type designation on the connec-
tion cable is mandatory.
20 | GB
 www.scheppach.com /  service@scheppach.com /  +(49)-08223-4002-99 /  +(49)-08223-4002-58
AC motor
• The mains voltage must be 220 - 240 V~
• Extension cables up to 25 m long must have a
cross-section of 1.5 mm
.
2
Connections and repairs of electrical equipment may
only be carried out by an electrician.
Please provide the following information in the event
of any enquiries:
• Type of current for the motor
• Machine data - type plate
• Machine data - type plate

10. Cleaning, maintenance and storage

m Important!
Pull out the power plug before doing any cleaning and
maintenance work on the equipment. Risk of injury
from electric shock!
m Important!
Wait until the equipment has cooled down complete-
ly! Risk of burns!
m Important!
Always depressurize the equipment before carrying
out any cleaning and maintenance work! Risk of in-
jury!
Cleaning
• Keep the equipment free of dirt and dust as far as
possible. Wipe the equipment with a clean cloth or
blow it down with compressed air at low pressure.
• We recommend that you clean the equipment im-
mediately after you use it.
• Clean the equipment regularly with a damp cloth
and some soft soap. Do not use cleaning agents
or solvents; these may be aggressive to the plastic
parts in the equipment. Ensure that no water can
get into the interior of the equipment.
• You must disconnect the hose and any spraying
tools from the compressor before cleaning. Do not
clean the compressor with water, solvents or the
like.
Service information
Please note that the following parts of this product
are subject to normal or natural wear and that the
following parts are therefore also required for use
as consumables.
Wear parts*: coupling
* Not necessarily included in the scope of delivery!