EMERGENCY
EMERGENCY
If it is necessary to replace the electronic control panel because of a failure, and you
cannot find immediately the spare part, it is possible to create an easy emergency-cir-
cuit in this way:
Disconnect the tension from the unit.
Open the switchboard.
Inside the switchboard there are two terminals on whose plate the letters "A" and "B" are
reproduced. Near the letters two wires are indicated with a corresponding colour and imme-
diately after you can find (into brackets) the numbers corresponding with the terminals of
the electronic control panel.
Disconnect the wires indicated on the plate from the electronic control panel and connect
them with the corresponding emergency terminal.
Connect an electromechanical thermostat with a capacity of at least 6 inductive ampere
on the other end of the terminal.
Put the thermostat bulb in the cold room and program the cold room temperature.
Close the switchboard and supply power to the unit again.
In case of emergency only the cooling-phase will go on working; as the defrost
is excluded, we advise you to reduce the openings of the doors and the move-
ment of the product to the minimum.
When you change the electronic control panel, you have to restore all the con-
nections following the wiring diagram of the unit.
11
GB
GB