TECHNICAL SPECIFICATIONS
Technology:
Detection mode:
Detection width:
Mounting Height:
Remission factor:
Angular resolution:
Testbody:
Emission characteristics:
IR laser:
Supply Voltage:
Power Consumption:
Response time:
Output:
Rating:
Input:
Rating:
Test Input*:
Temperature Range:
Degree of Protection:
Humidity:
Vibrations:
Material:
Norm Conformity:
Mounting angle (rotational):
Tilt angle:
Pollution on front screens:
* SEE APPLICATION NOTES OR CONTACT BEA FOR TECHNICAL SUPPORT
For version compatibiltiy serial number information, please see Application Note 76.0017 or contact BEA for
technical support.
BEA, the sensor manufacturer, cannot be held responsible for incorrect installations or inappropriate adjustments of the sensor/device; therefore, BEA
does not guarantee any use of the sensor outside of its intended purpose.
BEA strongly recommends that installation and service technicians be AAADM-certifi ed for pedestrian doors, IDA-certifi ed for doors/gates, and factory-
trained for the type of door/gate system.
Installers and service personnel are responsible for executing a risk assessment following each installation/service performed, ensuring that the sensor
system installation is compliant with local, national, and international regulations, codes, and standards.
Once installation or service work is complete, a safety inspection of the door/gate shall be performed per the door/gate manufacturer recommendations
and/or per AAADM/ANSI/DASMA guidelines (where applicable) for best industry practices. Safety inspections must be performed during each service
call – examples of these safety inspections can be found on an AAADM safety information label (e.g. ANSI/DASMA 102, ANSI/DASMA 107, UL 325).
Verify that all appropriate industry signage and warning labels are in place.
Page 16 of 16
Page 16 of 16
laser, time-of-flight measurement
presence
20 – 48"
(measured from leading edge to sensor LED)
(measured from finished floor to sensor LED)
75 – 98"
> 2%
2.56°
28" (H) x 12" (W) x 8" (D) according to UL325
wavelength 905 nm; max. output pulse power 35 W (CLASS 1)
12 – 30 VDC (15 W Class II)
< 15 W
typ. 40 ms (max. 80 ms)
4 electro-mechanic relays (galvanic isolated - polarity free)
All outputs Class 2 supply, 12 – 24 VAC / 12 – 30 VDC, max. 15 W
2 optocouplers (galvanic isolated – polarity-free)
12 – 24 VAC / 12 – 30 VDC, 50/60 HZ, max. 15 W
8 – 15 VDC
-13 – 121 °F (-25 – 55 °C)
Hub: IP20/NEMA 1
Sensor: IP53/NEMA 3
0 – 95% non-condensing
< 2 G
PC/ASA
EN 60825-1-Eye-safety class 1 IR laser (905 nm), UL325, UL60730
35° fixed
0 – 5° (for angles less than 5°, contact Tech Support)
max. 30%; homogenous
Specifications are subject to change without prior notice.
All values have been measured in specific conditions.
BEA INSTALLATION/SERVICE COMPLIANCE EXPECTATIONS
Tech Support: 1-800-407-4545 | Customer Service: 1-800-523-2462
General Tech Questions: Tech_Services@beainc.com | Tech Docs: www.BEAinc.com
75.5753.14 LZR-MICROSCAN T 20180208
75.5753.14 LZR-MICROSCAN T 20180208