WARNING
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR IN-
JURY TO PERSONS, OBSERVE THE FOLLOWING:
1. Use this unit only in the manner intended by the manufacturer.
If you have questions, contact the manufacturer at the address
or telephone number listed in the warranty.
2. Before servicing or cleaning unit, switch power off at service
panel and lock the service disconnecting means to prevent
power from being switched on accidentally. When the service
disconnecting means cannot be locked, securely fasten a
prominent warning device, such as a tag, to the service panel.
3. Installation work and electrical wiring must be done by a
qualified person(s) in accordance with all applicable codes
and standards, including fire-rated construction codes and
standards.
4. Sufficient air is needed for proper combustion and exhausting
of gases through the flue (chimney) of fuel burning equip-
ment to prevent backdrafting. Follow the heating equipment
manufacturer's guideline and safety standards such as those
published by the National Fire Protection Association (NFPA),
and the American Society for Heating, Refrigeration and Air
Conditioning Engineers (ASHRAE), and the local code authori-
ties.
5. When cutting or drilling into wall or ceiling, do not damage
electrical wiring and other hidden utilities.
6. Ducted fans must always be vented to the outdoors.
7. Acceptable for use over a tub or shower when connected to
a GFCI (Ground Fault Circuit Interrupter) - protected branch
circuit (ceiling installation only).
8. This unit must be grounded.
CAUTION
1. For general ventilating use only. Do not use to exhaust hazard-
ous or explosive materials and vapors.
2. This product is designed for installation in ceilings up to a
12/12 pitch (45 degree angle). Duct connector must point up.
DO NOT MOUNT THIS PRODUCT IN A WALL.
3. To avoid motor bearing damage and noisy and/or unbalanced
impellers, keep drywall spray, construction dust, etc. off power
unit.
4. Please read specification label on product for further informa-
tion and requirements.
Installer: Leave this manual with
the homeowner.
CLEANING & MAINTENANCE
For quiet and efficient operation, long life, and attractive appear-
ance - lower or remove grille and vacuum interior of unit with the
dusting brush attachment.
The motor is permanently lubricated and never needs oiling. If the
motor bearings are making excessive or unusual noises, replace
the blower assembly (includes motor and impeller).
OPERATION
Use an on/off switch or speed control to operate this ventilator.
See "Connect Wiring" for details.
WARRANTY
BROAN-NUTONE THREE YEAR LIMITED WARRANTY
Broan-NuTone warrants to the original consumer purchaser of its products
that such products will be free from defects in materials or workmanship
for a period of three years from the date of original purchase. THERE ARE
NO OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING, BUT
NOT LIMITED TO, IMPLIED WARRANTIES OF MERCHANTABILITY OR
FITNESS FOR A PARTICULAR PURPOSE.
During this three-year period, Broan-NuTone will, at its option, repair or
replace, without charge, any product or part which is found to be defective
under normal use and service.
THIS WARRANTY DOES NOT EXTEND TO FLUORESCENT LAMP
STARTERS, TUBES, HALOGEN AND INCANDESCENT BULBS, FUSES,
FILTERS, DUCTS, ROOF CAPS, WALL CAPS AND OTHER ACCESSO-
RIES FOR DUCTING. This warranty does not cover (a) normal maintenance
and service or (b) any products or parts which have been subject to mis-
use, negligence, accident, improper maintenance or repair (other than by
Broan-NuTone), faulty installation or installation contrary to recommended
installation instructions.
The duration of an implied warranty is limited to the three-year period as
specified for the express warranty. Some states do not allow limitation on how
long an implied warranty lasts, so the above limitation may not apply to you.
BROAN-NUTONE'S OBLIGATION TO REPAIR OR REPLACE, AT BROAN-
NUTONE'S OPTION, SHALL BE THE PURCHASER'S SOLE AND EX-
CLUSIVE REMEDY UNDER THIS WARRANTY. BROAN-NUTONE SHALL
NOT BE LIABLE FOR INCIDENTAL, CONSEQUENTIAL OR SPECIAL
DAMAGES ARISING OUT OF OR IN CONNECTION WITH PRODUCT
USE OR PERFORMANCE. Some states do not allow the exclusion or
limitation of incidental or consequential damages, so the above limitation
may not apply to you.
This warranty gives you specific legal rights, and you may also have other
rights, which vary from state to state. This warranty supersedes all prior
warranties.
To qualify for warranty service, you must (a) notify Broan-NuTone at the
address or telephone number stated below, (b) give the model number and
part identification and (c) describe the nature of any defect in the product or
part. At the time of requesting warranty service, you must present evidence
of the original purchase date.
Broan-NuTone LLC, 926 W. State Street, Hartford, Wisconsin 53027
www.broan.com
800-558-1711
Register your product online at: www.broan.com/register
MODEL QT130E
Page 1

Publicidad

Tabla de contenido
loading

Resumen de contenidos para Broan QT130E

  • Página 1 This warranty supersedes all prior warranties. impellers, keep drywall spray, construction dust, etc. off power To qualify for warranty service, you must (a) notify Broan-NuTone at the unit. address or telephone number stated below, (b) give the model number and part identification and (c) describe the nature of any defect in the product or 4.
  • Página 2: Typical Installations

    MODEL QT130E Page 2 TYPICAL INSTALLATIONS PLAN THE INSTALLATION COOKING AREA Do not install above or inside this area. Housing mounted to joists. NOT FOR USE IN Cooking A COOKING AREA. Equipment Floor INSULATION (Place around and ROOF CAP* over fan housing.)
  • Página 3 MODEL QT130E Page 3 INSTALL HOUSING & DUCT CONNECT WIRING 1. Bend housing tabs. Use a pliers to bend housing TABS out to 90 TABS 2. Mount SPACER housing to (use for mounting to I-Joist) joist. Hold housing in place so that...
  • Página 4: Service Parts

    MODEL QT130E Page 4 INSTALL GRILLE 6. Finish ceiling. Install ceiling material. Cut out around housing. 7. Attach grille to housing. Replacement parts Squeeze grille can be ordered on our springs and insert website. Please visit us them into tabs at www.broan.com...
  • Página 5 PROPÓSITO PARTICULAR. de Calefacción, Refrigeración y Aire Acondicionado (American Durante este período de tres años, Broan-NuTone, a su criterio, reparará o reem- Society for Heating, Refrigeration and Air Conditioning Engi- plazará, sin cargo alguno, cualquier pieza o producto que se encuentre defectuoso bajo condiciones normales de uso y servicio.
  • Página 6: Instalaciones Típicas

    MODELO QT130E Página 6 INSTALACIONES TÍPICAS PLANIFICACIÓN DE LA INSTALACIÓN ÁREA QUE COCINA No instale sobre o dentro de esta área. Montaje de cubierta en viguetas. NO PARA EL USO EN UN Equipo ÁREA QUE COCINA. para cocinar Piso AISLAMIENTO...
  • Página 7: Instale La Cubierta

    MODELO QT130E Página 7 CONEXIÓN ELÉCTRICA INSTALE LA CUBIERTA Y EL CONDUCTO 1. Doble las lengüetas de la cubierta. Con un alicate, doble las LENGÜETAS de la LENGÜETAS cubierta a 90 2. Monte la SEPARADOR (se usa para el montaje cubierta en a la vigueta “I”)
  • Página 8: Piezas De Repuesto

    MODELO QT130E Página 8 INSTALE LA REJILLA 6. Termine el cielo raso. Instale el material del cielo raso. Recorte alrededor de la cubierta. 7. Acople la Las piezas de rejilla a la recambio se cubierta. pueden ahora pedir en nuestro Web site.

Tabla de contenido