The start of pulse generation occurs after the validation of the last
flashing digit provided that the preset time is coherent (<24)
☛
If the programmed time is less than two hours ahead of the time
base hour, no pulse will be sent until the times match. The circuit will then
automatically enter normal operation (1 or 2 pulses per minute). Otherwise,
the circuit will send rapid pulses (30 per minute) until the times match, then
☛
When the NO mode is confirmed, distribution is halted and the display
☛
In case of issue on the clock line (short circuit in / / or open line
in series), the ALARM message is displayed alternately with the time
of the circuit at a rate of half a second and the generation of pulses is
5.3. WEEkLY PROGRaMMInG OF a cIRcUIt
Each relay can be programmed to obtain the activation of a weekly event occurring on the
same day or the same week's period.
The choice of the periods is the following:
►
Mo-Fr (from Monday to Friday),
►
Sa-Su (from Saturday to Sunday),
►
Mo-Su (from Monday to Sunday, so all days),
►
Mo-Tu (from Monday to Tuesday),
►
Th-Fr (from Thursday to Friday)
►
Using the "MEnU" button, select
the menu:
►
Confirm by pressing «EntER»:
this screen appears and the indi-
cation «c1» flashes.
50
automatically switch back to normal operation.
switches back to the basic screen automatically.
automatically stopped.
SCHEDULING
AN EVENT
FRI 22 FEBR 2013
11:42:45 (LOCAL)
SCHEDULING
AN EVENT
RELAY: C1
00 SEC
MON
MDE-Radio-Timing-GTC-3080V2.3
PULSE
08:00