MMD-AP0726H✽ to AP0966H✽
◆ Slim Ducted type
Air discharge
The air discharge duct is connected.
◆ Floor Console Exposed type
Air filter
Filters out dust.
(Inside the return air grille)
◆ Floor Console Recessed type
Air discharge
Ground screw
Equipped on the electrical
control box.
Air intake
Air in the room enters here.
9-EN
Air discharge
Connect a discharge duct.
Electrical control box
The ground screw is provided in the
electrical control box.
Air intake
Connect a suction duct.
Drain pan
Air intake
The air suction duct is connected.
Ground screw
Equipped on the electrical
control box.
Discharge louver
Controls discharge air directions.
Ground screw
Equipped on the electrical
control box.
Return air grille
Air in the room enters here.
Drain funnel (with strainer)
Accessory to be attached at the site
Air filter
Filters out dust.
(Inside the return air grille)
Front panel (lower)
– 5 –
3
Wired remote control
This remote control can control up to 8 indoor units.
The remote control has two sections: the display section and the operation section.
Display section
In the display below, all the icons are shown. When the unit is in operation,
only the relevant icons appear.
• When the circuit breaker is turned on the first time,
remote control.
• While this display is flashing, the model is being automatically confirmed.
Wait till
disappears before you use the remote control.
3
19
4
5
6
20
15
17
1
SETTING display
Displayed during timer setup or other settings.
2
Operation mode
The selected operation mode is displayed.
3
Check display
Displayed while the protective device works or a
problem occurs.
4
Timer display
Indicates time on the timer.
(Indicates a check code when a problem occurs)
5
Timer Mode display
Displays the timer mode.
6
Filter display
, reminder to clean the air filter.
flashes on the
TEMP.
TIMER SET
TIME
SAVE
FILTER
RESET
TEST
SET
CL
SWING/FIX
1
2
7
8
9
22
18 16
23
14
7
TEST run display
Displayed during a test run.
8
Louver position display
Displays louver position.
* Only for 4-way cassette type, Compact 4-way
cassette type, Ceiling type, High wall type.
9
Swing display
Displayed during up/down louver movement.
10
Set temperature display
The selected set temp. is displayed.
11
Remote control sensor display
Displayed while the remote control sensor is used.
Partition line
Display
section
ON / OFF
Operation
FAN
MODE
section
VENT
UNIT LOUVER
10
11
21
12
13
10-EN