available usage
time?
9.
Can the PPP be
used in
combination with
a 12 V fully
automatic
satellite
installation?
10
Does the nose
.
wheel weight
have any
importance?
11
Is there any
.
capacity loss
over the years?
12
Is it possible to
.
connect the PPP
both to 12 V and
230 V
simultaneously?
13
To what extent is
.
it allowed to
completely
discharge the
PPP?
1.
Is the PPP
protected
against:
a. Short circuit?
b. Overload?
2.
Can the PPP
catch fire in the
event of a short
circuit?
Yes. Use the "domestic" output to
power the system. Disconnect the
system after use to prevent
unnecessary discharge.
Yes, the more weight on the
shaft/nose wheel, the deeper it
can dig into the ground. This will
cause added load for the system
leading to poor performance.
Yes.
Yes.
This is allowed. Recharge
immediately after use to prevent
premature failure.
IV. TECHNOLOGY
a. Yes.
b. Yes, by means of electronic
switches and an internal non-
replaceable fuse.
No. There is an electronic short-
circuit and overload protection.
The PPP contains LiFePO4 cells,
which in case of short circuit do
not catch fire as opposed to
lithium manganese and lithium
polymer cells used in laptops,
mobile phones and model aero
13