Installation test (Duct)
Once you have completed the installation of the dryer, use this
test to make sure the condition of the exhaust system is adequate
for proper operation of the dryer. This test should be performed
to alert you to any serious problems in the exhaust system of your
home.
FLOW SENSE
that automatically detects blockages and restrictions in dryer
ductwork. Keeping ductwork clean of lint buildup and free of
restrictions allows clothes to dry faster and reduces energy use.
NOTE
The dryer should be cool before starting this test. If the dryer
was warmed up during installation, run the AIR DRY cycle for a
few minutes to reduce the interior temperature.
door.
Do not load anything in the drum for this test, as in may affect
the accuracy of the results.
This button sequence activates the installation test. The code
will display if the activation is successful.
The dryer will start the test, which will last about two minutes.
The heat will be turned on and the temperatures in the drum
will be measured.
TM
, an innovative sensing system
INSTALLATION INSTRUCTIONS
During the two minute test cycle, monitor the FLOW SENSE
display on the control panel. If no bars are displayed, when
the cycle ends, the exhaust system is adequate. If the exhaust
system is severely restricted, the display will show four bars.
Other problems may also be shown with error codes. Refer to
the next page for error code details and solutions.
OK
Four bars indicates that the exhaust system is severely restricted.
Have the system checked immediately, as performance will be
poor.
At the end of the test cycle,
will end and the dryer will shut off automatically after a short
delay.
29
TM
RESTRICTED
will display. The test cycle