6 - ADVANCED PROGRAMMING MODE
6600 / 6665
Note :
1. Push the
button once
per display.
2. Option settings may be
changed by pushing the
and
set buttons
The valve is in service position set at 12:01. To enter in the complete
level, push and hold the
button for 5 seconds.
The board will show first all parameters of the basic programming
mode, and then following settings:
6.1. Flow rate (Fr) in l/min
(1)
Ex.: 8,6 l/mn
not adjustable
6.2. Days since the last regeneration (d)
Ex.: 2 days
not adjustable
6.3. Prior service volume used in litre (1)
Ex.: 3483 l
not adjustable
6.4. Reserve capacity (rc) in litre (1)
Ex.: 852 l
not adjustable
6.5. Previous days water usage (Pd) in litre (1)
Ex.: 284 l
not adjustable
6.6. System capacity in m3 °tH (c)
Ex.: 100 m3 °tH
6.7. Cycle #1 :
Ex.: 6 minutes
6.8. Cycle #2 :
Ex.: 60 minutes
6.9. Cycle #3 :
Ex.: 10 minutes
6.10. Cycle #4 :
Ex.: 12 minutes
6.11. Cycle #5
Only for 6 cycles mode
6.12. Cycle #6
Only for 6 cycles mode
Note : not viewed if cycle #5 is set on OFF.
6600 – 6665 – 6700 – 6765
[Fr - - 8.6]
[d - - - - 2]
[E - -3483]
[rc - - 852]
[Pd - -28.4]
(1)
[C- - - 100]
[1 - - - 6.0]
[2 - - 60.0]
[3 - - 10.0]
[4 - - 12.0]
[5 - -OFF]
[6 - -OFF]