420010309700 Multiflam 500.1 - 600.1 PR/PR
EN
Main switch I/0
Lock-out lamp
Resistor lamp
Heavy oil lamp
Gas lamp
POSITION OF IGNITION ELECTRODES
NOZZLE CLEANING AND REPLACEMENT
Use only the suitable box wrench provided for this operation to
remove the nozzle, taking care to not damage the electrodes. Fit the
new nozzle with the same care.
Note: Always check the position of electrodes after having replaced
the nozzle (see illustration). A wrong position could cause ignition
troubles.
DESCRIPTION OF THE CONTROL PANEL OF THE BURNER
HLBT
HLR
HL
OIL
HL
GAS
3 ÷ 4 mm
SAL
0
I
45
RWF 40
SAMA
POS 0: STOP
SAMA
POS 1: UP
POS 2: LOW
POS 3: AUTO
GEFRAN
SAOG
I 0 II
POS 0: STOP
POS 1: NAFTA
POS 2: GAS
SARA
0
I
POS 0: OFF
POS 1: ON
SA
S.R
36
5 ÷ 6 mm
RWF 40 regulator
Selector (0-STOP / 1-Hight Flame /
2-Low Flame / 3-Automatic)
GEFRAN regulator
Selector (GAS / 0 / HEAVY OIL)
Auxiliaries Resistances switch
Reset button