Conveying capacity (tonnes/hour) for standard pre-cleaned and
dried grain:
Type
TRL20 & TF20
2,5
TRL40 & TF40
4,3
TRL55/75 & TF55
4,7
TRL55/75 & CA20
8,7
TRL100 & CA20
15,6
TRL150 & CA20
15,6
TRL150 & CA30
23,3
TRL200 & CA20
15,7
TRL200 & CA30
26,9
TRL300 & CA30
26,5
TRL300 & CA40
38,6
TRL500 & CA40
52,9
The above capacities apply to cleaned grain of a mois-
ture content of max. 15% at an air temperature of 20°C
and a barometric pressure of 760 mm Hg.
•
Lengths include two 90° bends, 4 m vertical pipe +
outlet cyclone
•
For each metre increase in the vertical pipeline,
the total pipeline is increased by 1,2 m.
•
For each metre by which the vertical pipe line is
reduced, the total pipe line length is reduced by
1,2 m.
Each bend, in addition to the two bends of the stand-
ard pipeline, corresponds to one metre of extra length.
This extra length depends on the conveying capacity
and the blower size.
10
20
30
2,0
1,7
3,6
3,0
3,9
3,3
7,4
6,4
13,8
11,9
15,5
15,4
19,7
17,0
15,6
15,5
25,5
22,1
25,5
24,5
33,1
28,8
47,0
42,3
Conveying length in meters
40
50
60
1,4
1,2
1,0
2,6
2,3
2,0
2,9
2,5
2,2
5,6
4,9
4,4
10,3
9,1
8,0
15,0
13,2
11,1
14,8
13,0
11,5
15,5
15,4
15,3
19,4
17,4
15,3
23,5
22,5
20,4
25,4
22,7
20,4
38,3
34,9
32,1
The following table shows the extra horizontal length
per bend for the different blowers:
Blower
TRL20 + TF20
TRL40 + TF40
TRL55/75 + TF55
TRL55/75 + CA20
TRL100
TRL150
TRL200
TRL300
TRL500
80
100
120
0,7
0,5
1,6
1,2
1,8
1,4
1,1
3,5
2,9
2,4
6,4
5,2
4,3
9,3
7,6
6,2
9,2
7,5
6,1
12,6
10,4
8,4
12,5
10,3
8,3
16,8
14,1
12,0
16,8
14,1
12,0
27,4
23,8
21
Extra length (m)
4,5
5,7
5,9
7,4
8,9
9,2
9,6
10,2
11,3
150
200
0,8
1,8
3,2
2,0
4,6
2,9
4,6
2,9
6,8
4,6
6,8
4,6
9,6
6,9
9,6
6,9
17,6
13,6
15