Lux Knob Setting; Operation; Auto Mode; Walk Test - koban KDP7 Serie Manual De Instrucciones

Detector de presencia de superficie
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

KDP7
Motion detector light control

LUX knob setting

• Set LUX knob value the position of , the minimum LUX value will be
approx 5lux. KDP7 has no reaction against the movement as the actual light
level is higher than 5lux.
• Set LUX knob value at the position of
performed, in such way KDP7 responds to the movement at any light level.
• To adjust LUX knob according to user's desires in between the position of
& .

Operation

Auto mode

KDP7 Motion Detector Light Control can automatically turn the light ON or
OFF depending on what the value of LUX and Timer are set. The light will turn
on when ambient light level applies to LUX setting and the motion sensor
is activated as the moving object is in detection coverage, and the lamp will
turn off automatically when time set is reached.
Conversely, when ambient light level does not apply to LUX setting, the
sensor can not be activated and the light will not turn on even there is
moving object in the detection coverage.

Walk test

The purpose of the walk test is to select a proper installation place and gain
the desired detection coverage under auto mode. Please turn TIME knob
to "-", LUX knob to " ", and METER knob to "+", then refer to the
following steps conducting a walk test.
The KDP7 needs to warm up for about 1min after power on. During test,
the light will turn on for about 6sec when the detector is activated once the
moving object starts to walk from inside the detection pattern (See FIG.12).
Please stop walking as soon as the light turns on. If the moving object is
keeping walking in the detection area, the timer will reset and re-count for
another 6sec.
Instructions manual |
20
the maximum LUX value will be
www.grupotemper.com

Publicidad

Capítulos

Tabla de contenido
loading

Este manual también es adecuado para:

Kdp7 150Kdp7 180

Tabla de contenido