17 Regulator
18 Indicator "Current adjustment"
19 Button "A" (current adjustment)
20 Indicator "PRE FLOW" (gas purge time adjustment
before welding)
21 Indicator "POST FLOW" (gas purge time adjust-
ment after welding)
22 Button F5 (purge time adjustment)
23 Indicator "2T" (two-stroke torch operation mode)
24 Indicator "4T" (four-stroke torch operation mode)
25 Button F4 (torch operation mode selection)
26 Indicator "INITIAL CUR�" (adjustment of the start-
ing current)
27 Indicator "UP SLOPE" (adjustment of the current
increase time from the starting current to the op-
erating one)
28 Indicator "DOWN SLOPE" (adjustment of the
welding current decrease)
29 Indicator "CRATER CUR�" (adjustment of the cra-
ter filling current)
30 Button F3 (setting operating parameters for weld-
ing in a pulse mode)
31 Indicator "FREQ" (frequency adjustment when
working in a pulse mode)
32 Indicator "PEAK" (adjustment of the upper level
of the welding current when operating in a pulse
mode)
33 Indicator "BASE" (adjustment of the lower level
of the welding current when operating in a pulse
mode)
34 Button F2 (setting pulse mode parameters)
35 Indicator "LIFT TIG" (contact method for the arc
ignition)
36 Indicator "HF" (high-frequency method for the arc
ignition)
37 Indicator "Pulse mode"
38 Indicator "MMA welding"
39 Button F1 (welding method selection)
40 Electrode holder (assembled) *
41 Earth clamp (assembled) *
42 Torch *
43 Ceramic nozzle of the torch *
44 Collet *
45 Collet holder *
46 End cap (long) *
47 End cap (short) *
48 Indicator "TIG welding"
49 Button F2 (adjustment of the welding current de-
crease time / adjustment of the gas purge time
after welding)
50 Button "MMA welding"
51 Ground wire *
52 Clamp *
53 Gas pressure regulator with a gas flow regulator *
54 Hose *
55 Gas cylinder (argon) *
56 Torch control cable *
57 Connector of the torch connection cable *
58 Nut of the torch control cable connector *
59 Power connector of the torch *
60 Torch body *
61 Tungsten electrode *
* Optional extra
Not all of the accessories illustrated or described
are included as standard delivery.
Installation and regulation of machine
elements
Before carrying out any works on the machine it
must be disconnected from the mains.
Do not draw up the fastening ele-
ments too tight to avoid damaging the
thread.
Mounting / dismounting / setting-up of
some elements is the same for all ma-
chine models, in this case specific mod-
els are not indicated in the illustration.
Mounting / dismounting of a plug, current-carrying
cable, stationary network connection
Some machine models are supplied without plugs
and / or current-carrying cables - they must be installed
before the beginning of the operation�
Machines can also be connected to the network on a
stationary basis (not through a socket)�
Note: the stationary connection of the
machine to the network as well as instal-
lation or replacement of current-carrying
cables, plugs and other electrical units
must be performed only by a qualified electrician or
circuit installer authorized to perform such works.
Connection to the earthing loop (see fig. 1)
Using grounding bolt 3 connect one grounding wire
clamp 51 to the machine (see fig. 1). Connect the sec-
ond grounding wire clamp 51 to the working grounding
loop�
Gas connection (see fig. 2)
• Install a gas pressure regulator 53 on a gas cylin-
der 55 (see fig. 2). Attention: flow rate meter flask
should be installed vertically upward.
• Put clamps 52 on the ends of hose 54� Connect one
end of the hose 54 to a connection pipe of the gas
pressure regulator 53, the other one - to the connec-
tion pipe 4� Fix the hose 54 on connection pipes by
clamps 52�
Connecting / disconnecting welding cables (see
fig. 3-5)
During TIG welding (see fig. 3-4)
• If necessary to attach the connector to the welding
cable, follow the steps shown in fig. 3.1, 4.1.
• If electrode holder 40 is installed, disconnect it�
• Connect earth clamp 41 (see fig. 3.2, 4.2) to the ma-
chine�
• Connect the welding torch 42 to the machine:
• connect a welding torch control cable� Set a con-
trol cable connector in socket 6 and tighten a nut 58
by hand� During installation, pay attention that locat-
ing tab inside of a socket fits a location slot of the
cable connector (see fig. 3.3, 4.3);
English