golmar T3301ML Manual De Instalación página 22

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

MODULE PROGRAMMING
Coming from previous page
It defines the activation code of the panic function.
3
0
It defines the contact type of the relay n.1.
4
1
Select 0 for normally open operation.
Select 1 for normally closed operation.
0
1
or
Factory default: 0 (n/o).
It defines the activation type of the relay n.1.
5
1
Select 0 for single shoot operation.
Select 1 for stable operation.
Factory default: 0 (single shoot).
0
1
or
It defines the activation time of the relay n.1.
6
1
Select a value from 01 to 20 (seconds).
Factory default: 03 seconds.
0
5
It defines the activation time of the relay n.2.
6
2
Select a value from 01 to 20 (seconds).
Factory default: 03 seconds.
0
5
It defines the activation time of the panic output.
6
3
Select a value from 01 to 20 (seconds).
Factory default: 03 seconds.
0
5
F
unction fields and values.
Proceed as detailed on 11 field.
In case of power supply failure and n/c operation,
the relay will switch to n/o status.
Only valid when programmed as single shoot.
This relay only operates as single shoot.
Continue
40
41
Coming from previous page
7
0
*
8
0
*
9
0
0
It's possible to activate both relays simultaneously. Simply repeat one of the activation codes
for both relays.
On systems that use the power supply module to activate the connected devices
(i.e. two lock releases) simultaneously, the maximum load of this power supply must be
calculated. If necessary, an additional power supply can be used to activate these devices.
The connection of an additional TF-104 transformer, to activate a second lock release,
is shown on page 44.
MODULE PROGRAMMING
F
It defines the installer PIN code to enter into programming
mode.
A 6 digits code must be always used. Once this code
has been introduced, 2 acoustic tones will be heard:
introduce the code again and 4 slow acoustic tones
*
will be heard to confirm the changes.
Factory default: 271828.
It defines the user PIN code to enter into programming
mode.
A 6 digits code must be always used.
Proceed as described on the previous field.
Factory default: 314159.
*
It allows to enable or disable the acoustic signal that's
reproduced when a key is pressed. This function
hasn't effect during programming mode.
Select 0 to disable this function.
Select 1 to enable this function.
1
or
Factory default: 1 (enabled).
unction fields and values.
D
uplicated codes.