QuickStar t
for single gate application
LA500DC
Primary 24 VDC Actuator Arm for
single swing gate applications
LA500DCS
Secondary 24 VDC Actuator Arm for
dual swing gate applications
LA500PKGU
Single Arm Package
2016 UL 325 Gate Operators require use of LiftMaster
external monitored entrapment protection devices.
This QuickStart is intended to highlight a single gate
application. Each application is unique and it is the
responsibility of the purchaser, installer and end user to ensure
that the total gate system is installed and operated properly.
Refer to the installation manual for complete information
regarding installation, testing, and programming.
845 Larch Avenue
Elmhurst, Illinois 60126-1196
LiftMaster.com
01-38141
© 2016, LiftMaster – All Rights Reserved
Position the brackets
4" (10.2 cm)
maximum
Post
Bracket
Gate hinge center
7-3/4"
(19.7 cm)
8-1/2"
Post bracket
(21.6 cm)
Install the Control Box
Check national
and local codes
for proper depth
INSTALLATION
Attach the brackets and operator
Gate Bracket
6-1/2"
(16.5 cm)
35-1/2" (90.2 cm)
2-1/4" (6.4 cm)
Gate Bracket
Earth Ground Rod
Install the earth ground rod within 3 feet (.9 m)
of the control box. The ground wire must be a
single, whole piece of wire.
Connect the Operator Arm to the Control Box

Publicidad

loading

Resumen de contenidos para LiftMaster LA500 Serie

  • Página 1 8-1/2" Post bracket (21.6 cm) Gate Bracket 2016 UL 325 Gate Operators require use of LiftMaster external monitored entrapment protection devices. This QuickStart is intended to highlight a single gate Connect the Operator Arm to the Control Box Install the Control Box Earth Ground Rod application.
  • Página 2: Wiring And Adjustments

    Connect the earth ground rod, incoming power, and system and REQUIRES the addition of a LiftMaster external The gate MUST be attached to batteries (see images below). The operator can be wired for 2.
  • Página 3: Démarrage Rapide

    Vérifier les codes l’installation, la mise à l’essai et la programmation. nationaux et locaux pour la profondeur appropriée. 845 Larch Avenue Elmhurst, Illinois 60126-1196 LiftMaster.com 01-38141 © 2016, LiftMaster – Tous droits réservés...
  • Página 4 (voir les illustrations 2. Placer un objet solide entre la barrière ouverte et une structure rigide. protection de LiftMaster contre le piégeage (capteur limites et de la force. En cas ci-dessous). L’actionneur peut être câblé pour 120 ou 240 V S’assurer que la barrière, l’objet solide et la structure rigide peuvent...
  • Página 5: Instalación

    Verifique los códigos (de una sola pieza). nacionales y locales para averiguar la profundidad correcta. 845 Larch Avenue Elmhurst, Illinois 60126-1196 LiftMaster.com 01-38141 © 2016, LiftMaster – Reservados todos los derechos de ley...
  • Página 6 2. Colocar un objeto sólido entre la trayectoria de apertura y una eléctrica y las baterías (ver las siguientes ilustraciones). El monitoreada de LiftMaster para CADA zona de atrapamiento límites y la fuerza. Si se cometiera estructura fija. Verificar que el portón, el objeto sólido y la operador puede cablearse para 120 o 240 VCA según el...

Este manual también es adecuado para:

La500dcLa500dcsLa500pkgu