The Interior Light
HWCB 15, HWCB 30, HWCB 45. HWCB 60, HWCB 60D
o When the control panel is unlocked, you can use the light button
to switch the interior light on and off.
o The light will remain on unless it is turned off manually by
pressing the light button.
Setting The Temperature Range
o The appliance is with 4 temperature ranges for option, the ranges list of
each model is as below.
o To change temperature range, when the control panel is locked,
press the temperature minus button for 3 seconds, the display
window will flash "E"--"F"--"H"--"L" in loop with a sound of beep
by every pressing.
o Leave the display window flashing for 3 seconds, a beep will sound to
indicate that the setting is confirmed.
HWCB 15, HWCB 30, HWCB 45, HWCB 60D
o The default range of Single Zone is E: 5-22 °C (41-72 °F).
* For HWCB 60D, the defualt temperature setting range is E: 5-22 °C (41-72 °F)
for Left Zone, F: 2 - 20 °C (36°F-68°F) for Right Zone.
HWCB 60
o The default range of Dual Zone is E: 5-12 °C (41-54 °F) for the upper zone
and 12-22 °C (54-72 °F) for the lower zone
Display
E (Default)
F
H
L
Display
Temp. Range (Single Zone)
E (Default)
F
H
L
Upper Zone
5 - 12 °C (41°F-54°F)
2 - 12 °C (36°F-54°F)
5 - 12 °C (41°F-54°F)
2 - 10 °C (36°F-50°F)
5 - 22 °C (41°F-72°F)
2 - 20 °C (36°F-68°F)
10 - 19 °C (50°F-66°F)
0 - 20 °C (36°F-68°F)
Temp.Range (Dual Zone)
12 - 22 °C (54°F-72°F)
12 - 20 °C (54°F-68°F)
8 - 19 °C (46°F-66°F)
12 - 22 °C (54°F-72°F)
.9.
Lower Zone