GAS COOKTOPS
Contents
Gas Cooktops
2
Specifications
3
Installation
5
Troubleshooting
5
Features and specifications are subject to change at any
time without notice. Visit wolfappliance.com/specs for the
most up-to-date information.
|
2
English
WF Intl GCooktops IG MultiLang 824551A 10-13.indd 2
Important Note
To ensure this product is installed and operated as safely
and efficiently as possible, take note of the following types
of highlighted information throughout this guide:
IMPORTANT NOTE
highlights information that is especially
important.
CAUTION
indicates a situation where minor injury or product
damage may occur if instructions are not followed.
WARNING
states a hazard that may cause serious injury or
death if precautions are not followed.
IMPORTANT NOTE:
Save these instructions for the local
electrical inspector.
WARNING
This appliance shall be installed in accordance with the
regulations in force and only used in a well ventilated
space. Read the instructions before installing or using
this appliance.
Product Information
Important product information including the model and
serial number are listed on the product rating plate. The
rating plate is located on the bottom of the cooktop. Refer
to the illustration below.
If service is necessary, contact Wolf factory certified service
with the model and serial number.
RATING PLATE
Rating plate location.
Installation Requirements
If a cooktop is being installed above an oven, a minimum
of 6 mm is required between units. A minimum 140 mm is
required from the bottom of the cooktop to combustible
materials.
Electrical
Installation must comply with all applicable electrical codes.
Locate the electrical supply as shown in the illustrations
on page 4. A separate circuit, servicing only this appliance
is required. A ground fault circuit interrupter (GFCI) is not
recommended and may cause interruption of operation.
ELECTRICAL REQUIREMENTS
GAS COOKTOP
Electrical Supply
grounded (earthed)
220-240 V AC, 50/60 Hz
Service
10 amp dedicated circuit
Receptacle
grounding-type (earthed)
IMPORTANT NOTE:
Connection of this appliance should be
through a fused connection unit or a suitable isolator, which
complies with national and local safety regulations. The
on/off switch should be easily accessible after the appli-
ance has been installed. If the switch is not accessible after
installation (depending on country) an additional means of
disconnection must be provided for all poles of the power
supply. When switched off there must be an all pole contact
gap of 3 mm in the isolator switch. This 3 mm contact dis-
connect gap must apply to any isolator switch, fuses and/or
relays according to EN60335.