3. Installation and commissioning
Attachment example (magnetic switch to support bar)
GB
Remove the support bar (1) by loosening the mounting screws (2) and
■
removing the retaining plates (3) from the bypass stand seat
Push the magnetic switch (4) onto the support bar (1)
■
Attach the support bar (1) to the bypass tube (5) again using the
■
retaining plates (3) and mounting screws (2)
Push the magnetic switch to the height of the required switch point
■
and fix in place by tightening the screws (6) (the switch point is
marked on the product label)
Fig. 4: Mounting the magnetic switch (model MS, MV, MVT, MEx)
14
These magnetic switches are fixed to a separately attached
support bar (fig. 4).
Please make sure during mounting that the cable entry and/
or the plug are pointing downwards. To guarantee a safe
switching function, the magnetic switch housing must rest
against the bypass tube.
KSR KUEBLER Operating Instructions Bypass Level Indicator – BNA