SORHEA
Mode "AND"
Simultaneous interruption of 2
cells for intrusion alarm.
Adjusting response time of the
intrusion alarm:
50ms
to
700ms
Attention: Adjust the response time using the provided potentiometer.
Adjustment of the response time allows adaptation of the detection sensitivity of the barrier
environment. A long response time reduces the sensitivity.
Response
time
Note: In modes "OR" and "AND/OR" the minimum response time is 100ms. If the potentiometer is
adjusted to between 50ms and 100ms, the response time will be set to 100ms.
Description of operating modes
Mode "OR"
Interruption of one of the 2
cells for intrusion alarm.
Response time
Adjusting response time of the
intrusion alarm:
100ms
to
ON
ALIGN. CHANNEL
1
2
3
4
ON
OFF
Potentiometer for intrusion
alarm response time
50 ms
100 ms
700ms
MASTER
DELAY
MODE
RX
5
ON
OFF
50
700
ms
200 ms
(default value)
- 29 -
BIRIS II 50/100/200
Mode "AND/OR"
Simultaneous interruption of 2
cells for intrusion alarm.
Interruption of the bottom cell for
a minimum of 1.5 s for intrusion
alarm.
Adjusting response time of the
intrusion alarm:
100ms
to
700ms
Fixed response time for the
bottom cell set at 1.5s.
ON
6
400 ms
700 ms