5.2.1 Placement
The appliance has been designed
with the utmost care and attention and
conforms to current international safety
standards and directives. For safe
operation of the appliance, the place
must meet these requirements:
• Keep the appliances away from hot
surfaces, moisture and sharp edges.
• Place an appliance that is fitted with an
electrical plug near an easily accessible
earthed wall socket.
If the appliance is not supplied with
a fitted electrical plug, ensure that a
professional authorized electrician
establishes a permanent connection
point to the appliance protected by an
earth leakage circuit breaker of 30 mA
in which all phases and the NEUTRAL
connection can easily be disconnected
(minimum 3 mm contact distance).
• Do not let the mains cable hang over
the edge of the table or counter, or
touch hot surfaces.
• Place an appliance that is to be filled
with water near an easy‑to‑operate
water connection point.
• Place an appliance from which water
must be drained near a water discharge
point.
• Make sure that there is sufficient space
around the appliance for ventilation.
Always keep the front and back of
the appliance accessible for repair
purposes.
Never place the appliance in the
following environments:
• In an area where water is sprayed.
• In a room where the temperature can
drop to below 0°C / 32°F.
CAUTION!
If the appliance does become
frozen, disconnect the power
and water supply to the
appliance and call the service
engineer.

5.2.2 Electrical connection

WARNING!
This appliance must be
earthed.
The following operations should be
carried out by a qualified electrician.
If your appliance comes fitted with a plug
that does not fit your socket, the plug
should be cut off from the mains lead,
and an appropriate plug fitted, as below.
WARNING!
Very carefully dispose of the
cut off plug.
With alternative plugs not incorporating
a fuse, the circuit must be protected by
fuse according to the local regulations.
If your appliance is not fitted with a plug,
please follow the instructions provided
below.
In the event of a new plug being fitted,
please note:
• The wire which is coloured green
and yellow must be connected to the
terminal in the plug which is marked
with the letter E or the earth symbol or
coloured green or green and yellow.
• The wire which is coloured blue must
be connected to the terminal which is
marked with the letter N or coloured
black.
• The wire is coloured brown must be
connected to the terminal which is
marked with the letter L or coloured red.