USA
Safety notes
Protection against scalding
It is recommended that near points of discharge with
particular sensitivity to the outlet temperature
(hospitals, schools, nursing and retirement homes)
thermostatic devices should be installed which can limit the
water temperature to 109 °F (43 °C). The product includes an
appropriate temperature end stop. It is generally
recommended that the temperature of shower-systems should
not exceed 100 °F (38 °C) in nurseries and specific areas of
care centres. Use Grohtherm Special thermostats with special
handle to facilitate thermal disinfection and appropriate safety
end stop. Applicable standards (e. g. EN 806-2) and technical
regulations for drinking water must be observed.
Application
Thermostatic mixers are designed for hot water supplies from
pressurised storage heaters and offer the highest temperature
accuracy when used in this way. With sufficient power output
(from 18 kW or 250 kcal/min), electric or gas instantaneous
heaters are also suitable.
Thermostats cannot be used in connection with unpressurised
storage heaters (displacement water heaters).
All thermostats are adjusted in the factory at a flow pressure
of 3 bar on both sides.
Should temperature deviations occur on account of special
installation conditions, the thermostat must be adapted to local
conditions (see Adjusting, Calibration).
Specifications
Minimum flow pressure
Max. operating pressure
Recommended flow pressure
Test pressure
Flow rate at 43.5 psi flow pressure
26 128
Max. water temperature at hot water supply
Recommended max. flow temperature
(energy economy)
thermal desinfection possible
Safety stop
Hot water temperature at supply connection 4 °F higher than
mixed water temperature.
Cold water connection
Hot water connection
Minimum flow rate
If static pressure exceeds 72.5 psi, a pressure-reducing valve
must be fitted.
Installation
Flush piping system prior and after installation of fitting
thoroughly (Consider EN 806)!
Required dimensions, see dimensional drawings on fold-out
page I and Fig. [1] on fold-out page II.
Install S-unions and screw-mount the mixer, see fold-out
page II, Fig. [2].
Open cold and hot-water supply and check connections
for water-tightness.
Reversed connection (hot on right - cold on left). Replace
thermostatic compact cartridge, see Replacement Parts,
fold-out page I, Prod. no. 47 175 (1/2").
Adjusting
For temperature adjustment (calibration), see fold-out
page II, Fig. [3].
Temperature limitation
The safety stop limits the temperature range to 100 °F (38 °C).
The 100 °F (38 °C) limit can be overridden by pressing the
button, see Fig. [4].
Temperature end stop
If the temperature end stop is at 109 °F (43 °C), insert
accompanying temperature limiter in temperature selection
handle, see Fig. [4].
Installation of the shower rail, see fold-out page II, Figs. [5]
to [9].
When installing e.g. on plasterboard walls (not solid walls) it
must be assured that an appropriate reinforcement is in place
to ensure sufficient strength.
Installation of the head shower, see fold-out page III, Fig. [10].
Shut-off handle operation, see Fig. [11].
Prevention of frost damage
When the domestic water system is drained, thermostats must
be drained separately, since non-return valves are installed in
the hot and cold water connections. For this purpose, the
mixer must be removed from the wall.
Maintenance
Inspect and clean all parts, replace if necessary and lubricate
with special grease.
Shut off the hot and cold water supply.
Non-return valve, see fold-out page III, Fig. [12].
7.25 psi
Install in reverse order.
145 psi
Thermostatic compact cartridge, see fold-out page III, Fig. [13].
14.5 psi - 72.5 psi
Install in reverse order.
232 psi
Readjustment is necessary after every maintenance
operation on the thermostatic compact cartridge
approx. 8 L/min or 2.1 gpm
(see Adjusting).
158 °F
Aquadimmer, see fold-out page III, Fig. [14].
140 °F
Install in reverse order.
Shower, see fold-out page III, Fig. [15].
100 °F
The function of the SpeedClean nozzles is guaranteed for a
period of five years.
Thanks to the SpeedClean nozzles, which must be regularly
right
cleaned, limescale deposits on the rose can be removed by
left
simply rubbing with the fingers.
1.3 gpm
Replacement parts, see fold-out page I ( * = special
accessories).
Care
For directions on care, refer to the accompanying Care
Instructions.
Информация по технике безопасности
больницах, школах, домах для престарелых и инвалидов),
настоятельно рекомендуется устанавливать термостаты с
ограничением температуры до 43 °C. Данное изделие для
ограничения температуры имеет концевой упор. В
душевых установках в детских садах и специальных
помещениях домов для инвалидов рекомендуется не
превышать температуру 38 °C.
RUS
Предотвращение ожогов
В местах забора, где обращается особое
внимание на температуру на выходе (в
24