FOR USE WITH RANGEMASTER 60000 OR RM60000 SERIES OR 64000 SERIES RANGE HOODS
READ AND SAVE THESE INSTRUCTIONS
WARNING
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR
INJURY TO PERSONS, OBSERVE THE FOLLOWING:
1. Use this unit only in the manner intended by the manufac-
turer. If you have questions, contact the manufacturer at the
address or phone number listed in the warranty.
2. Before servicing or cleaning unit, switch power off at service
panel and lock the service disconnecting means to prevent
power from being switched on accidentally. When the service
disconnecting means cannot be locked, securely fasten a
prominent warning device, such as a tag, to the service panel.
3. Installation work and electrical wiring must be done by a
qualified person(s) in accordance with all applicable codes
and standards, including fire-rated construction codes and
standards.
4. Sufficient air is needed for proper combustion and exhaust-
ing of gases through the flue (chimney) of fuel burning
equipment to prevent backdrafting. Follow the heating equip-
ment manufacturer's guideline and safety standards such as
those published by the National Fire Protection Association
(NFPA), and the American Society for Heating, Refrigeration
and Air Conditioning Engineers (ASHRAE), and the local
code authorities.
PLAN THE INSTALLATION
ALL INSTALLATIONS
1. Locate the blower so the length of the duct run and number
of elbows needed are kept to a minimum.
2. Where possible, blower should be centered between wall
studs or roof rafters.
MODEL 335
EXTERIOR BLOWER
SOFFIT
WALL HOOD
CANOPY
(island canopy
available)
DUCT
OPENING
COVER PLATE
24" or 27"
TYPICAL ROOF MOUNTED INSTALLATION
(Vertical discharge)
INSTALLER: Leave This Manual With The Homeowner
HOMEOWNER: Use And Care Information On Page 4
EXTERIOR MOUNTED BLOWER
10" ROUND
DUCT
WALL HOOD
CANOPY
(island canopy
available)
ROUGH-IN
18"
PLATE
DUCT OPENING
TYPICAL WALL MOUNTED INSTALLATION
(Vertical discharge - elbow to horizontal)
MODEL 335
WARNING
5. When cutting or drilling into wall, or ceiling, do not damage
electrical wiring or other hidden utilities.
6. Ducted fans must always be vented to the outdoors.
7. To reduce risk of fire, use only metal ductwork.
8. This unit must be grounded.
CAUTION
1. For general ventilating use only. Do not use to exhaust
hazardous or explosive material and vapors.
2. To avoid motor bearing damage and noisy and/or unbal-
anced impellers, keep drywall spray, construction dust, etc.
off power unit.
3. Please read specification label on product for further informa-
tion and requirements.
4. Electrical circuit, including speed control, (if used), must be
rated 6 AMPS minimum.
SPECIFICATIONS
MODEL VOLTS
335
3. Avoid pipes, wires, or other ductwork that may be running
through the wall.
4. Wall mounted installation only: Make sure blower discharge
is at least 12" above any outside obstructions.
NOTE: Horizontal discharge requires relocation of the duct
opening cover plate. See hood manual for instructions.
10" ROUND ELBOW
10" ROUND DUCT
SOFFIT
MODEL
335
EXTERIOR
BLOWER
ROUGH-IN
PLATE
18"
12" MIN.
24" or 27"
ABOVE ANY
OBSTRUCTION
COVER PLATE
AMPS
CFM
120
3.0
1200
10" ROUND DUCT
SOFFIT
WALL HOOD
CANOPY
(island canopy
available)
18"
24" or 27"
ROUGH-IN
PLATE
TYPICAL WALL MOUNTED INSTALLATION
(Horizontal discharge)
DUCT SIZE
10" DIA.
DUCT
OPENING
COVER
PLATE
MODEL 335
EXTERIOR
BLOWER
12" MIN.
ABOVE ANY
OBSTRUCTION