READ AND SAVE THESE INSTRUCTIONS
WARNING
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY
TO PERSONS, OBSERVE THE FOLLOWING:
1. Use this unit only in the manner intended by the manufacturer.
If you have questions, contact the manufacturer at the address
or telephone number listed in the warranty.
2. Before servicing or cleaning unit, disable the ventilator by cover-
ing the solar panel with cardboard or disconnecting the wires
from the motor terminals (note wire locations when disconnect-
ing).
3. Installation work must be done by a qualified person(s) in ac-
cordance with all applicable codes and standards, including
fire-rated construction codes and standards.
4. If removing an existing 120 VAC powered attic ventilator, use
only a qualified person(s) to remove any electrical wiring in
accordance with all applicable codes and standards.
5. Sufficient air is needed for proper combustion and exhausting
of gases through the flue (chimney) of fuel burning equipment
to prevent backdrafting. Follow the heating equipment manufac-
turer's guidelines and safety standards such as those published
by the National Fire Protection Association (NFPA), and the
American Society for Heating, Refrigeration and Air Condition-
ing Engineers (ASHRAE), and the local code authorities.
6. When cutting or drilling into wall or ceiling, do not damage
electrical wiring and other hidden utilities.
TOOLS AND MATERIALS REQUIRED
r
Drill
r
1/4" Drill Bit
r
Sabre Saw or Keyhole Saw
r
Hammer
r
Ruler / Tape Measure
r
Pencil, Marker or Scribe
r
Utility Knife
r
Pry Bar (to remove roofing nails)
r
5/16" Socket and Extension
r
Roofing Cement
r
Galvanized #10 x 1" Pancake Head Wood Screws
MODELS 345SOBK • 345SOWW
CAUTION
1. For general ventilating use only. Do not use to exhaust hazard-
ous or explosive materials and vapors.
2. To avoid motor bearing damage and noisy and/or unbalanced
impellers, keep drywall spray, construction dust, etc. off power
unit.
3. This unit has an unguarded impeller. Do not use in locations
readily accessible to people or animals.
4. This ventilator operates when the solar panel is exposed to
sun light. To reduce risk of injury while installing, servicing or
cleaning unit, cover the solar panel with cardboard or discon-
nect the wires from the motor terminals (note wire locations
when disconnecting).
5. The recommended open air inlet for this ventilator is 2 square
feet. The best location for these air intake vents are under the
eaves with direct access to the attic. Failure to provide these
intakes could cause natural-draft gas appliances to backdraft.
6. Your attic fan installation will create a screened opening into
your attic space. During a heavy rain storm there could be a
light spray of rain into this attic space. This is a normal condi-
tion with all attic ventilators and will not cause any damage to
the structure. We recommend that you do not store any valu-
able articles directly under the fan opening in the roof.
7. This ventilator is intended for roof installation. Broan Models
353, 345GOBK & 345GOWW Gable Mount Ventilators are
available for side wall applications.
8. The plastic ventilator dome and base may be painted with
high quality paint. Follow the paint manufacturer's recommen-
dations for acrylic and ABS plastic as appropriate. Take care
to avoid getting paint on the solar panel.
9. This ventilator includes a permanently lubricated motor. Do
not oil or disassemble.
10. The installation instructions contained in this document are
only a recommendation and individual professionals may
have their own methods of installation. If your roof has an
existing warranty, installation of this product by anyone other
than those who installed the roof may jeopardize any future
warranty claim. Please check with the original installer of your
roof if this is a concern.
11. When working with asphalt shingles in cold weather (below
40
F), take care to avoid damage to the shingle edges and
o
corners.
12. For installations in climates where cold weather condensation
is not a concern, Broan Model CWT45 thermostat is available.
It disconnects power to the motor when the temperature drops
below 50
o
F. Power is applied to the motor when the tempera-
ture reaches 61
F.
o
Register your product online at:
www.broan.com/register
Page 1

Publicidad

Tabla de contenido
loading

Resumen de contenidos para Broan 345SOBK

  • Página 1 6. When cutting or drilling into wall or ceiling, do not damage 7. This ventilator is intended for roof installation. Broan Models electrical wiring and other hidden utilities. 353, 345GOBK & 345GOWW Gable Mount Ventilators are available for side wall applications.
  • Página 2 MODELS 345SOBK • 345SOWW Page 2 INSTALLATION Note: This ventilator is capable of replacing an existing 120 volt powered attic ventilator. Only a qualified per- son should remove any electrical wiring in accordance with local codes and standards. 3. Separate the dome from the base by removing four (4) sheet metal screws.
  • Página 3 MODELS 345SOBK • 345SOWW Page 3 6. From the roof side, using the guide hole as the center point, use a nail and string to scribe a 16-1/2” diameter 9. Drill a large starting hole for the sabre saw just inside of circle on the shingles.
  • Página 4 MODELS 345SOBK • 345SOWW Page 4 12. Apply a large bead of roofing cement in the molded 14. Using a good grade of roofing cement material, seal groove on the bottom side of ventilator base. Make sure shingles and all screw heads. DO NOT seal the bottom the arrow on the ventilator base is pointed toward the edge of the ventilator base.
  • Página 5: Service Parts

    MODELS 345SOBK • 345SOWW Page 5 SERVICE PARTS Replacement parts can now be ordered on our website. Please visit us at www.Broan.com Model Model 345SOBK 345SOWW Description (Black) (Weathered Wood) 77001311 77001313 Solar Panel Assembly (Dome) CWT45 CWT45 Thermostat (Optional)
  • Página 6 Customer shall properly notify Broan in writing and shall include with such notice a sales receipt or proof of purchase of the defective Product, and Broan at its option shall repair or replace the defective Product or component part without charge to Customer, except for: (A) costs incurred in transporting the Products or component parts to and from Broan’s designated dealer or its manufacturing plant in Hartford, Wisconsin;...
  • Página 7: Outils Et Matériel Requis

    Vis à bois galvanisées à tête applatie #10 x 1 po 12. Pour les installations dans les régions où la condensation par temps froid n'est pas un problème, le modèle Broan CWT45 thermostat est disponible. Il coupe le courant du moteur lorsque la température descend à...
  • Página 8 MODÈLES 345SOBK • 345SOWW Page 8 INSTALLATION Remarque : Ce ventilateur peut remplacer un ventila- teur électrique de 120 volts pour grenier. Seule une personne qualifiée peut enlever le câblage conformément aux codes et aux normes en vigueur. 3. Séparez le dôme du ventilateur de sa base en enlevant les quatre (4) vis à...
  • Página 9 MODÈLES 345SOBK • 345SOWW Page 9 6. De l’extérieur du toit et en utilisant l'avant-trou comme point central, à l'aide d'un clou et d'une corde, tracez 9. Percez un grand trou de départ pour la scie sauteuse un cercle de 42 cm (16-1/2 po) de diamètre sur les juste à...
  • Página 10 MODÈLES 345SOBK • 345SOWW Page 10 12. Appliquez un gros cordon d’enduit à toiture dans la 14. Imperméabilisez les bardeaux et les têtes de vis rainure du dessous de la base du ventilateur. Assurez- à l'aide d'un enduit à toiture de bonne qualité.
  • Página 11: Pièces De Rechange

    MODÈLES 345SOBK • 345SOWW Page 11 PIÈCES DE RECHANGE Les pièces de rechange peuvent être commandées sur notre site Web. Visitez notre site à www.Broan.com Modèle Modèle Repère 345SOBK 345SOWW Description (noir) (bois intempérisé) 77001311 77001313 Ensemble de panneau solaire (dôme)
  • Página 12 – Garantie exclusive limitée – Le contrat de garantie exclusive limitée (la « Garantie ») est conclu entre le client et Broan-NuTone LLC (« Broan »). Le client a lu attentivement cette garantie et convient que l’exécution des obligations de Broan ci-dessous lui fournira un recours adéquat qui servira aux fins essentielles de l’accord des parties relativement aux produits fabriqués par Broan et identifiés au verso de la présente (les...
  • Página 13: Ventilador Solar Para Ático De Montaje En El Techo

    7. Este ventilador está diseñado para instalarse en el techo. Los en Calefacción, Refrigeración y Aire Acondicionado (American ventiladores para montaje en hastial Broan Modelos 353, Society for Heating, Refrigeration and Air Conditioning 345GOBK y 345GOWW están disponibles para aplicaciones Engineers, ASHRAE), y las autoridades de los códigos locales.
  • Página 14: Instalación

    MODELOS 345SOBK • 345SOWW Página 14 INSTALACIÓN Nota: Este ventilador tiene capacidad para reemplazar un ventilador para ático existente de 120 voltios. Sólo el personal calificado debe quitar el cableado eléctrico de acuerdo con los códigos y las normas locales.
  • Página 15 MODELOS 345SOBK • 345SOWW Página 15 6. Desde el lado del techo, usando el orificio guía como punto central, use un clavo y un cordón para marcar un círculo de 16 1/2 pulg. (42 cm) de diámetro sobre 9. Perfore un orificio iniciador grande para la sierra de las tejas.
  • Página 16 MODELOS 345SOBK • 345SOWW Página 16 12. Aplique un cordón grande de cemento para techo en 14. Con un buen cemento con grado para techo selle todas la ranura moldeada en la parte inferior de la base del las tejas y las cabezas de los tornillos. NO selle el borde ventilador.
  • Página 17: Piezas De Servicio

    MODELOS 345SOBK • 345SOWW Página 17 PIEZAS DE SERVICIO Ahora se pueden hacer los pedidos de las piezas de repuesto en nuestro sitio Web. Visítenos en www.Broan.com Modelo Modelo Clave 345SOBK 345SOWW Descripción (Negro) (Madera curtida) 77001311 77001313 Conjunto del panel solar (domo)
  • Página 18: Garantía

    Garantía; ambos correrán a cargo del Cliente. No obstante cualquier disposición en la presente que señale otra cosa, esta Garantía no se ampliará para Broan ni la obligará a tomar medida alguna con respecto a: (A) Productos que hayan sido modificados, alterados, instalados, usados u operados de una manera que no sea recomendada por Broan, incluyendo cualesquiera Productos en los cuales se hayan instalado piezas no fabricadas ni aprobadas por Broan;...
  • Página 19 MODELS / MODÈLES / MODELOS 345SOBK • 345SOWW Page / Página 19...
  • Página 20 MODELS / MODÈLES / MODELOS 345SOBK • 345SOWW Page / Página 20 79040170D...

Este manual también es adecuado para:

345soww

Tabla de contenido