Kobalt XC302000 Manual Del Usuario página 11

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

ASSEMBLY INSTRUCTIONS
GROUNDING
This product must be grounded. In the event of an electrical short circuit, grounding reduces the risk of
electric shock by providing an escape wire for the electric current. This product is equipped with a cord
having a grounding wire with an appropriate grounding plug. The plug must be plugged into an outlet
that is properly installed and grounded in accordance with all local codes and ordinances. Do not use
grounding adapter.
WARNING
Risk of electric shock. Improper use of grounding
plug can result in a risk of electrical shock. Plug
must be plugged into an outlet that is properly
installed and grounded in accordance with local
codes and ordinances by a qualified electrician.
This product comes from the factory ready for use
on a nominal 120 volt circuit and has a grounding
plug similar to the plug illustrated in Figure 6. If
the listed conditions cannot be met or if nuisance
tripping of the current protection device occurs, it
may be possible to operate the compressor from
a 120 volt 20 amp circuit. Shown in Figure 6.
Check motor data plate for 240 volt compatibility.
A 240 volt unit must be operated on a 240 volt
circuit. The cord must only plug into a 240 volt
grounded outlet and may require a new cord and
plug. Shown in Figure 7. This product may be
modified to operate at 240V. To do so, a 240V
power cord needs to be purchased and installed
on the unit and wired into the pressure switch just
like the 120V cord. The panel on the back of the
motor needs to be opened and the flag terminals
need to be moved so that the brown wire that is
on terminal #4 is on terminal #2 and the orange
wire that is on terminal #1 needs to be moved to
terminal #4 (where the brown wire was originally).
Shown in Figure 8.
WARNING
All wiring and electrical connections should be
performed by a qualified electrician. Installation
must be in accordance with local codes and
national electrical codes.
If not properly grounded, this tool can
cause an electrical shock, particularly when used in
damp locations, in proximity of plumbing, outdoors.
6
Outlet - 120V / 20A
7
WARNING
Installation of grounding plug can result in electric
shock. When repair or replacement of the cord or plug
is required, do not connect the grounding wire to either
flat blade terminal. The wire with insulation having an
outer surface that is green with or without yellow stripes
is the grounding wire. Never connect green (or green
and yellow) wire to a live terminal.
11
Grounded
Outlet
Outlet - 120V / 15A
Ground
Pin
Grounded
Outlet
Outlet - 240V
Ground
Pin

Publicidad

Tabla de contenido

Solución de problemas

loading

Este manual también es adecuado para:

0905519

Tabla de contenido