Kobalt XC302000 Manual Del Usuario página 17

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

TROUBLESHOOTING
PROBLEM
POSSIBLE CAUSE
Large quantity of
1. Worn piston rings.
oil in the discharge
air
2. Compressor air intake
NOTE: In an oil-
lubed compressor
there will always
3. Excessive oil in compressor.
be a small amount
of oil in the air
4. Wrong oil viscosity.
stream.
Water in discharge
air / tank.
Motor hums and
1. Low voltage.
runs slowly or not
at all.
2. Use of extension cord.
3. Too many devices on same
4. Loose electrical connections.
5. Malfunctioning pressure
6. Malfunctioning check valve.
7. Defective unloader valve on
8. Defective motor capacitor(s).
9. Defective motor.
Reset
1. Lack of proper ventilation /
mechanism cuts
out repeatedly
2. Too many devices on same
or circuit breaker
trips repeatedly.
3. Restricted air intake.
4. Loose electrical connection.
restricted.
Normal operation. The
amount of water increases
with humid weather.
circuit.
switch - contacts will not
close.
pressure switch.
room temperature too high.
circuit.
CORRECTIVE ACTION
1. Replace with new rings. Maintain oil level and change oil
more frequently.
2. Clean or replace filter. Check for other restrictions in the
intake system.
3. Drain down to full level.
4. Use Mobil 1
10W-30 full synthetic.
®
1. Drain tank more often. At least daily.
2. Add a filter to reduce the amount of water in the air line.
1. Check incoming voltage. It should be approximately 120
volts. Low voltage could be due to wires (from breaker/fuse to
outlet) being too small in diameter and / or too long. Have
a qualified electrician check these conditions and make
repairs as needed.
2. Do not use an extension cord. Use longer air hose with larger
diameter.
3. Limit the circuit to the use of compressor only.
4. Check all electrical connections.
5. Replace pressure switch.
6. Replace check valve.
DANGER
Risk of Explosion. Do not
disassemble check valve with air
pressure in tank.
7. Replace unloader valve.
8. Replace capacitor(s).
9. Replace motor.
1. Move compressor to well-ventilated area.
2. Limit the circuit to the use of only the air compressor.
3. Clean or replace filter element.
4. Check all electrical connections.
17

Publicidad

Tabla de contenido

Solución de problemas

loading

Este manual también es adecuado para:

0905519

Tabla de contenido