- To start welding press the torch button.
- To adjust the welding parameters adjust the wire feed rate (where
provided) using the appropriate knob until even welding is obtained
(Fig. B-3).
SPOT WELDING FUNCTION (where provided)
- To change the welding time operate the adjustment knob (Fig.
B-5).
WARNING:
- In some models the wireguide tip is normally live; take care to
prevent unwanted strikes.
- The indicator light comes on when there is overheating and cuts off
the power supply; it will reset automatically within a few minutes,
after cooling down.
7. MAINTENANCE
WARNING! BEFORE CARRYING OUT MAINTENANCE
OPERATIONS MAKE SURE THE WELDING MACHINE IS
SWITCHED OFF AND DISCONNECTED FROM THE MAIN
POWER SUPPLY.
ROUTINE MAINTENANCE:
ROUTINE MAINTENANCE OPERATIONS CAN BE CARRIED OUT
BY THE OPERATOR.
Torch
- Do not put the torch or its cable on hot pieces; this would cause the
insulating materials to melt, making the torch unusable after a very
short time;
- Make regular checks on the gas pipe and connector seals;
- Every time the wire reel is changed, blow out the wire-guide
hose using dry compressed air (max. 5 bar) to make sure it is not
damaged;
- Before every use, check the wear and correct assembly of the
parts at the end of the torch: nozzle, contact tip, gas diffuser.
Wire feeder
- Make frequent checks on the state of wear of the wire feeder
rollers, regularly remove the metal dust deposited in the feeder
area (rollers and wire-guide infeed and outfeed).
EXTRAORDINARY MAINTENANCE
EXTRAORDINARY MAINTENANCE MUST ONLY BE CARRIED
OUT BY TECHNICIANS WHO ARE EXPERT OR QUALIFIED IN
THE ELECTRIC-MECHANICAL FIELD, AND IN FULL RESPECT
OF THE IEC/EN 60974-4 TECHNICAL DIRECTIVE.
WARNING! BEFORE REMOVING THE WELDING
MACHINE PANELS AND WORKING INSIDE THE MACHINE
MAKE SURE THE WELDING MACHINE IS SWITCHED OFF AND
DISCONNECTED FROM THE MAIN POWER SUPPLY OUTLET.
If checks are made inside the welding machine while it is live,
this may cause serious electric shock due to direct contact with
live parts and/or injury due to direct contact with moving parts.
- Inspect the welding machine regularly, with a frequency depending
on use and the dustiness of the environment, and remove the dust
deposited on the transformer, reactance and rectifier using a jet of
dry compressed air (max. 10 bar).
- Do not direct the jet of compressed air on the electronic boards;
these can be cleaned with a very soft brush or suitable solvents.
- At the same time make sure the electrical connections are tight and
check the wiring for damage to the insulation.
- At the end of these operations re-assemble the panels of the
welding machine and screw the fastening screws right down.
- Never, ever carry out welding operations while the welding machine
is open.
- After having carried out maintenance or repairs, restore the
connections and wiring as they were before, making sure they do
not come into contact with moving parts or parts that can reach high
temperatures. Tie all the wires as they were before, being careful
to keep the high voltage connections of the primary transformer
Fig. L
separate from the low voltage ones of the secondary transformer.
Use all the original washers and screws when closing the casing.
MANUALE ISTRUZIONE
ATTENZIONE:
PRIMA
DI
UTILIZZARE
ATTENTAMENTE IL MANUALE DI ISTRUZIONE.
SALDATRICI A FILO CONTINUO PER LA SALDATURA AD
ARCO MIG/MAG E FLUX PREVISTE PER USO INDUSTRIALE E
PROFESSIONALE.
Nota: Nel testo che segue verrà impiegato il termine "saldatrice".
1. SICUREZZA GENERALE PER LA SALDATURA AD ARCO
L'operatore deve essere sufficientemente edotto sull'uso sicuro
della saldatrice ed informato sui rischi connessi ai procedimenti
per saldatura ad arco, alle relative misure di protezione ed alle
procedure di emergenza.
(Fare riferimento anche alla norma "EN 60974-9: Apparecchiature
per saldatura ad arco. Parte 9: Installazione ed uso").
- Evitare i contatti diretti con il circuito di saldatura; la tensione
a vuoto fornita dal generatore può essere pericolosa in talune
circostanze.
- La connessione dei cavi di saldatura, le operazioni di verifica
e di riparazione devono essere eseguite a saldatrice spenta e
scollegata dalla rete di alimentazione.
- Spegnere la saldatrice e scollegarla dalla rete di alimentazione
prima di sostituire i particolari d'usura della torcia.
- Eseguire l'installazione elettrica secondo le previste norme e
leggi antinfortunistiche.
- La saldatrice deve essere collegata esclusivamente ad un
sistema di alimentazione con conduttore di neutro collegato
a terra.
- Assicurarsi che la presa di alimentazione sia correttamente
collegata alla terra di protezione.
- Non utilizzare la saldatrice in ambienti umidi o bagnati o sotto
la pioggia.
- Non utilizzare cavi con isolamento deteriorato o con
connessioni allentate.
- Non saldare su contenitori, recipienti o tubazioni che
contengano o che abbiano contenuto prodotti infiammabili
liquidi o gassosi.
- Evitare di operare su materiali puliti con solventi clorurati o
nelle vicinanze di dette sostanze.
- Non saldare su recipienti in pressione.
- Allontanare dall'area di lavoro tutte le sostanze infiammabili
(p.es. legno, carta, stracci, etc.).
- Assicurarsi un ricambio d'aria adeguato o di mezzi atti ad
asportare i fumi di saldatura nelle vicinanze dell'arco; è
necessario un approccio sistematico per la valutazione dei
limiti all'esposizione dei fumi di saldatura in funzione della
loro composizione, concentrazione e durata dell'esposizione
stessa.
- Mantenere la bombola al riparo da fonti di calore, compreso
l'irraggiamento solare (se utilizzata).
- Adottare un adeguato isolamento elettrico rispetto la torcia,
il pezzo in lavorazione ed eventuali parti metalliche messe a
terra poste nelle vicinanze (accessibili).
Ciò è normalmente ottenibile indossando guanti, calzature,
copricapo ed indumenti previsti allo scopo e mediante l'uso
di pedane o tappeti isolanti.
- Proteggere sempre gli occhi con gli appositi filtri conformi
- 8 -
(IT)
LA
SALDATRICE
LEGGERE