Drufosmart
7. Operation
Turn the unit on by means of the main
switch (43) at the back of the unit. By
this the display (27) at the front of the
7.1 Adjustment heating time
By means of the turnable pressure cont-
roller (44) every time between 0:05 min.
and 9:55 min. can be adjusted by turn-
ing the controller clockwise. Adjustment
is effected in 5 sec. steps.
28
unit will be activated and shows 0:00.
An acoustic signal shows that the unit
is ready for operation.
Please refer to the enclosed information
folder in order to find out the optimum
times for Dreve thermoforming foils.
7.2 Start of programme
Before starting the adjusted heating
responding handle (5) just up to the
time put a corresponding blank into
mechanical interlock in the centre of the
the plate reception (11) and fix it by
unit. Close the ventilation valve (12) of
means of the tension ring (13).
the tension ring (13). In order to start
the heating process press the turnable
pressure controller (44). The display
shows a countdown towards 0:00 of
the adjusted time.
Info
For safety reasons the heating is
equipped with a final switch and
only works in swivelled in posi-
tion after having started a pro-
The model can either be put onto the
gramme. If the heating carrier (20)
nub plate (6) or fixed by taking out the
is swivelled outwards at the han-
nub plate and embedding it into gran-
dle (5) after having started a pro-
gramme, the heating process will
ules directly in the insert bowl.
be interrupted automatically. The
Info
indication in the display will stop
For an optimum adaptation of the
and show the remaining time. By
blank towards the model always
swivelling the heating carrier (20)
place the models in a way that
back in the programme will be re-
the anterior teeth are directed
activated.
towards the centre of the blank.
Attention! The swivelling housing
When using hard blanks it is rec-
of the heating element reaches
ommended to embed the mod-
high temperatures. Therefore it
els into granules. Models that
must not be touched – even not
are placed onto the nub plate
for short moments.
should not exceed a max. height
of 23 mm.
After the adjusted time has elapsed,
there will be an acoustic signal, the
Swivel the plate reception inwards at
indicator in the display will blink
the handle (10) just up to the mechani-
for 4 seconds and the cooling time
cal interlock in the centre of the unit
will be counted up again automati-
(magnetic interlocking). Also swivel in
cally.
the heating element (20) at the cor-
29