Heating Modulis RTS Ramp
Problems
The Heating Modulis RTS
Ramp does not heat up
suffi ciently. (next)
The Heating Modulis RTS
Ramp does not switch on.

8.2 Replacing a lost or broken control point

Caution: This reset is carried out if all the RTS control points have been lost or broken.
Caution! This reset removes all control points but retains the favourite
heat level programmed.
Caution! Only switch off the power to the Heating Modulis RTS Ramp
to be reset!
CAUTION! Do not use an Inis RT/Inis RTS control point for resetting
1) Cut the power supply for 2 seconds.
2)
Switch the power supply back on for approximately 10 seconds (for
at least 5 seconds but no longer than 15 seconds).
3)
Cut the power supply for 2 seconds.
4)
Switch the power supply back on: the heating lamp fl ashes slowly.
5)
Briefl y press the PROG button on the new RTS control point (f):
-
The heating lamp will come on then go out again to indicate that
the new RTS control point has been programmed into the Heating
Modulis RTS Ramp.
8.3 Restoring the original confi guration
Caution! This reset removes all control points and resets the favourite heating level to 33% of the
total power.
Caution! Only switch off the power to the Heating Modulis RTS Ramp
to be reset!
Caution! Do not use the Inis RT/Inis RTS control point for resetting!
1) Cut the power supply for 2 seconds.
2)
Switch the power supply back on for approximately 10 seconds (for
at least 5 seconds but no longer than 15 seconds).
3)
Cut the power supply for 2 seconds.
4)
Switch the power supply back on: the heating lamp fl ashes slowly.
5)
Press the PROG button on the RTS control point until the heating
lamp comes on then goes out twice in succession: all control points
have been removed.
-
Follow the procedures in the section entitled "Commissioning" to
add RTS control points.

9. Technical data

Radio frequency
Power supply
Maximum total power
Index protection rating
Operating temperature
Safety level
24
5061611X02_HMR_Ramp_RTS.indb 24
Possible causes
The capacity of the Heating Modulis RTS
Ramp is not suffi cient.
The correct fuse has not been fi tted to the
equipment.
One or more heating lamps is blown or
broken.
The heating lamp(s) linked to the Heating
Modulis RTS Ramp exceed 2000 W.
433.42 MHz
230 V ~ 50 Hz
2000 W
IP24
- 20°C to + 60°C
Category II
Solutions
See the heated surface in the technical data.
Check the rating of the fuse. To operate the ramp
correctly, a 16 A delay fuse is required.
Replace the heating lamp(s).
Ensure that the heating lamp(s) linked to the
Heating Modulis RTS Ramp do not exceed 2000
W in total.
OFF
1
2 seconds.
OFF
3
2 seconds.
5
PROG.
f
OFF
1
2 seconds.
OFF
3
2 seconds.
5
PROG.
Number of programmable RTS
control points
Dimensions (mm)
Weight (kg)
Heating lamp
Service life (hours)
2
Heating surface (m
)
Copyright © 2008 Somfy SAS. All rights reserved.
Installation guide
ON
2
10 seconds.
ON
4
...
a
ON
2
10 seconds.
ON
4
...
12 maximum
483 x 176 x 230
3.5
Philips® HeLeN
5000
16
25/05/09 18:41:06