PARAMETER SETTING

If the parameters are changed after self-learning has been carried out, ensure the installation conforms to all
relevant standards.
Menu [Display]
Value
Language [LAnGUAGE]: to select the language for displaying information on the control unit screen.
French [Fra]
English [Eng]
Spanish [Esp]
German [Deu]
Italian [Ita]
Self-learning [AutoSet]: to start self-learning for the gate travel.
Parameters [PArAM]: to change the torque, speed and slowing down values for the motorisation.
Automatic closure time
Between 3 and 120 seconds
[tcA]
Opening motor torque
Between 1% and 99%
[oP. t]
Closing motor torque
Between 1% and 99%
[cLS.t]
Opening motor torque
Between 1% and 99%
while slowing down
[oP. t Slow]
Closing motor torque
Between 1% and 99%
while slowing down
[cLS. t SLow]
Normal opening speed
Between 1 second and 2
time [norM. oP. SPEED]
minutes
Normal closing speed
Between 1 second and 2
time [norM. cLS. SPEED]
minutes
Slowing down speed
0 - No slowing down
[SLow SPEED]
1 - Slowing level 1 (1/2)
2 - Slowing level 2 (1/3)
3 - Slowing level 3 (1/4)
Logic [LoGIc]: to select the motor operating mode and devices.
Automatic closure [tcA]
ON: Activates automatic
closure
OFF: Deactivates automatic
closure
3 Step
ON: Activates the 3 step logic.
[3 STEP]
OFF: Activates the 4 step logic.
Blocking impulses
ON: In opening mode only
[IbL oPEn]
OFF: None
Photoelectric cell
ON: In closing mode only.
operation
[Photoc. oPEn]
OFF: In opening and closing
mode.
Photoelectric cell test
ON: Activates the cell autotest
[tESt Phot]
function.
OFF: Deactivates the cell
autotest function.
Gate open indicator
ON: The output between
[ScA 2ch]
terminals 14 and 15 has been
confi gured as the gate open
indicator.
Pre-warning
ON: With pre-warning
[PrEAL]
OFF: Without pre-warning
Sustained action
ON: Operation with sustained
[hoLd-to-rUn]
action activated.
OFF: Operation with
impulse action, according to
3 or 4 step logic.
Copyright © 2008 Somfy SAS. All rights reserved.
By
Comments
default
Fra
10 s
Setting the time delay for automatic reclosing (If tcA is activated in
LoGic)
80%
The setting for the minimum motor torque value needed to move the
gate is carried out during auto-programming.
Refer to the paragraph entitled "Display of the motor torque values
50%
during operation of the motorisation" pg. 13 to set the motor torque
values.
50%
50%
15 s
The slowing down time during opening and closing can be set by
changing the "normal speed time"; the higher the normal speed
travel, the shorter the slowing down time.
15 s
E.g.: if the duration of an opening manoeuvre is 15 seconds, for a
slowing down time of 3 seconds, the "normal speed time" must be set
to 12 seconds.
3
0 - Normal speed
1 - Average speed
2 - Slow speed
3 - Very slow speed
OFF
The gate closes automatically after the programmed time delay.
OFF
3 STEP = operation in semi-automatic mode (see "User's manual" pg. 3).
4 STEP = operation in sequential mode (see "User's manual" pg. 3).
OFF
Impulses during opening have no effect.
OFF
In closing mode, the gate stops then reverses its movement.
In opening mode, cells are inactive.
In closing mode, the gate stops and reverses its movement once
the cells are no longer obstructed.
In opening mode, the gate stops then continues its movement
once the cells are no longer obstructed.
OFF
See the diagram for connection of the cells with autotest pg. 9 and 10.
OFF
With pre-warning: the integrated fl ashing amber light comes on
approximately 3 seconds before motorisation starts.
Without pre-warning: the integrated fl ashing amber light comes
on when motorisation starts.
OFF
Operation in hold-to-run mode, only with a wired control: continuous
movement while the control button remains pressed.
Elixo 500 24 V
11