General Safety Precautions; Ec Declaration Of Conformity; Technical Details; Electrical Connections - DITEC RO2H Manual De Instalación

Tablero eléctronico para automación radius y ollye
Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 15

GENERAL SAFETY PRECAUTIONS

GB
This installation manual is intended for professionally
competent personnel only.
The installation, the power connections and the settings must
be completed in conformity with Good Working Methods and
with the regulations in force. Before installing the product,
carefully read the instructions. Bad installation could be ha-
zardous.
The packaging materials (plastic, polystyrene, etc.) should not
be discarded in the environment or left within reach of children,
as these are a potential source of hazard. Before beginning the
installation check that the product is in perfect condition.
Do not install the product in explosive areas and atmospheres:
the presence of flammable gas or fumes represents a serious
threat to safety.
The safety devices (photocells, sensitive edges, emergency
stop, etc.) must be installed taking into account: the provisions
and the directives in force, Good Working Methods, the instal-
lation area, the functional logic of the system and the forces
developed by the motorised door or gate.
Before making power connections, check that the rating
corresponds to that of the mains supply A multipolar di-
sconnection switch with a contact opening gap of at least 3 mm
must be included in the mains supply. Check that upstream of
the electrical installation an adequate residual current circuit
breaker and an overcurrent cut out are fitted. When requested,
connect the motorised door or gate to an effective earthing
system carried out as indicated by current safety regulations.
During installation, maintenance and repair operations, cut
off the power supply before opening the cover to access the
electrical parts.
To handle electronic parts, wear earthed antistatic con-
ductive bracelets. The manufacturer of the motorisation
declines all responsibility in the event of components which
are not compatible with the safe and correct operation of the
product. For repairs or replacements of products only original
spare parts must be used.
1.

ELECTRICAL CONNECTIONS

1.1 Commands
Control
0
3
N.O.
0
4
N.O.
RO2H - IP1918
Function
OPENING
OPERATOR PRESENCE
DEPENDENT CONTROL
PARTIAL OPENING
CLOSING
HOLD TO RUN FUNCTION

EC DECLARATION OF CONFORMITY

Manufacturer:
DITEC S.p.A.
Address:
via Mons. Banfi, 3
21042 Caronno P.lla (VA) – ITALY
Herewith declares that the control panel RO2H (with receiver
433.92 MHz) is in conformity with the provisions of the following
EC directives:
Low Voltage Directive 73/23/EEC;
EMC Directive 89/336/EEC;
R&TTE Directive 1999/5/EC.
Caronno Pertusella,
31-01-2007

TECHNICAL DETAILS

Power supply
Motor output RADIUS
Motor output OLLY E
Temperature
RO2H dimensions
CONT3 dimensions
Radio frequency
Memorizable radio codes
APPLICATIONS
RO2H
The opening or step-by-step operation is activated when the contact
closes (see paragraph 1.4).
Note: a 0-4 command causes the stop during an opening manoeuvre.
The automation opens when the contact is pressed for more than 2 se-
conds and stops when the contact is released.
The two wings on the RADIUS automation stop together.
(Only RADIUS) During the opening operation from a closed position, a
second opening command stops the operation.
The closing or step-by-step operation is activated when the contact
closes (see paragraph 1.4).
Note: a 0-3 command causes the stop during a closing manoeuvre.
The automation closes when the contact is pressed for more than 2 se-
conds and stops when the contact is released.
6
Fermo Bressanini
(President)
RO2H
230 V~ / 50-60 Hz
12 V= / 2 x 1,4 A
19 V= / 1 x 1,8 A
-20° C / +55° C
166x64x40
200x92x55
433,92 MHz
200
Description

Publicidad

Tabla de contenido
loading

Tabla de contenido