5.4 CLADDING
The stove must be placed inside a suitable cladding,
A) inspection door on the right side with key lock
(to prevent access to children)
B) a door for access to the tank for loading the
pellets
C) a grid for heat discharge into the hood
D)
E) predisposition for placement of the control
panel
F) element of access to the ash tray and to the
two side compartments below
G) vents for the distribution of hot air
H)
fan and by-pass valve on the rear side
I)
front opening for inspection of the gear-motor
and upper sensor in the combustion chamber.
there is a minimum distance of at least 5 mm.
treatment and be protected by screens made of

5.5 COMBUSTION AIR

During operation the stove takes in a certain amount
of air from the room where it's installed; this air must
be replaced through an opening to the outside from
the room
If the wall behind of the stove is an outside wall,
make an opening for drawing in combustion air
dimensions shown on the product data sheet.
A permanent non-closable vent cover must be
placed on the outside of the opening; in especially
windy areas or places exposed to bad weather,
install rain and wind protection elements.
Make sure that the air vent is located in such a
way that it can't be accidentally obstructed.
If it's not possible to make a fresh air opening in
the wall behind the stove (not a perimeter wall),
an opening must be made on the wall in the room
where the stove is installed that faces the outside.
If no fresh air opening can be made in the room, it
can be made in an adjacent room as long as the
two rooms are connected by a ventilation grill.
If there are other heating appliances in the same
room, the fresh air vents must guarantee the
required volume of air for correct operation of all
the appliances.
If one or more exhaust fans (range hoods) are
installed and operating in the room where the
stove is located, combustion problems may occur
due to a lack of combustion air.In this case it is
necessary to properly resize the air intake.
INSTALLATION
Fig. 5.1
Fig. 5.2
C
G
G
I
F
D
D
H
B
E
A
D
PA
37