6-digit user codes, press
user number is entered, LED1 on any enabled readers will begin to flash.
2.
Badge any card. The user card information for the entered user number will be
cleared and LED1 will stop flashing.
3.
After about 40 seconds, all the readers in the system will be updated with the new
user card information.
Location 0 Badge Functions (3 segments, BD)
Program the functions that are performed when:
Segment 1: (Single Badge Function): A card is badged once.
Segment 2: (Double Badge Function) A card is badged twice within the 2
Badge/Hold Time as programmed at Location 244, Segment 1. (Default is 1.)
Segment 3: (Single Badge Hold Function): A card is badged and held at the reader
for the duration of the 2 Badge/Hold Time (Location 244, Segment 1). (Default is 1.)
Segment 1
Segment 2
Segment 3
8
h
followed by [0]-[0] and the 3-digit user number. If a valid
A 6. L
OCATIONS
Single Badge Function
Send Code Entry function to the control panel
1
Arm Away
2
Arm Stay mode
3
Disarm
4
Activate Aux/KeyFob Function 1 (see control panel events)
5
Activate Aux/KeyFob Function 2 (see control panel events)
6
Broadcast an X-10 function (see Location 241)
7
Send a Request to Exit (RTE) and activate the relay driver output.
8
(Default is On.)
Double Badge Function
Send Code Entry function to the control panel
1
Arm Away
2
Arm Stay mode
3
Disarm
4
Activate Aux/KeyFob Function 1 (see control panel events)
5
Activate Aux/KeyFob Function 2 (see control panel events)
6
Broadcast an X-10 function (see Location 241)
7
Send a Request to Exit (RTE) and activate the relay driver output.
8
(Default is On.)
Single Badge Hold Function
Send Code Entry function to the control panel
1
Arm Away
2
Arm Stay mode
3
Disarm
4
Activate Aux/KeyFob Function 1 (see control panel events)
5
Activate Aux/KeyFob Function 2 (see control panel events)
6
Broadcast an X-10 function (see Location 241)
7
Send a Request to Exit (RTE) and activate the relay driver output.
8
(Default is On.)