Descargar Imprimir esta página

Crow SWAN 1000 Instrucciones De Instalación página 2

Publicidad

S W A N 1 0 0 0
DETECTOR PASIVO INFRAROJO Y MICROONDAS CON INMUNIDAD ANIMALES
CONFIGURACIÓN DEL DETECTOR
INDICACION DE ALARMA POR LED
Interruptor 1 del dipswitch DIP-4 se usa para
configurar el LED habilitado / deshabilitado
Posición arriba – ON - LED HABILITADO
El LED ROJO se activa cuando el detector esta en
condición de alarma.
Posición abajo – OFF - LED DESHABILITADO
El LED esta Deshabilitado.
Nota: el estado del interruptor "LED" no afecta al
funcionamiento del relé.
Cuando un intruso es detectado, el LED se activa y el
relé se activa durante 2 segundos en condición de
alarma.
LED INDICADORES:
AMARILLO LED – detector MW
VERDE
LED – detector PIR
ROJO
LED - Alarma
AJUSTES DE LA SENSIBILIDAD PIR
Interruptor 2 del dipswitch DIP4 se usa para
configurar la función PULSE para proveer al PIR de
un control de sensibilidad acorde con el entorno.
Posición abajo – OFF – Alta sensibilidad
Para enotrnos estables.
Posición arriba – ON – Baja sensibilidad
Para entornos hostiles.
AJUSTES DE LA SENSIBILIDAD DEL MW
Interruptor 3 del dipswitch DIP4 se usa para
configurar la función MW para proveer al MW de un
control de sensibilidad acorde con el entorno.
Posición abajo – OFF – Alta sensibilidad
Para operación normal—detección inmediata.
Posición arriba – ON – Baja sensibilidad
Para entornos hostiles..
CONFIGURACIÓN INMUNIDAD ANIMALES
Interruptor 4 del dipswitch DIP4 se usa para
configurar la opción inmunidad animales- Desde
15Kg hasta 25Kg, dependiendo del peso del animal..
Posición arriba - ON
Inmunidad para animales de hasta 15 kg
Posición abajo - OFF
Inmunidad animales de hasta 25 kg
USTED PUEDE RESETEAR EL DETECTOR
DESCONECTANDO ALIMENTACIÓN Y VOVIENDOSELA
A DAR PASADOS UNOS SEGUNDOS..
CROW ELECTRONIC ENGINEERING LTD. ("Crow") - WARRANTY POLICY CERTIFICATE
This Warranty Certificate is given in favor of the purchaser (hereunder the "Purchaser") purchasing the products directly from Crow or from its authorized distributor.
Crow warrants these products to be free from defects in materials and workmanship under normal use and service for a period of 1 year from the last day of the week and
year whose numbers are printed on the printed circuit board inside these products (hereunder the "Warranty Period").
Subject to the provisions of this Warranty Certificate, during the Warranty Period, Crow undertakes, at its sole discretion and subject to Crow's procedures, as such
procedures are form time to time, to repair or replace, free of charge for materials and/or labor, products proved to be defective in materials or workmanship under normal
use and service. Repaired products shall be warranted for the remainder of the original Warranty Period.
All transportation costs and in-transit risk of loss or damage related, directly or indirectly, to products returned to Crow for repair or replacement shall be borne solely by the
Purchaser.
Crow's warranty under this Warranty Certificate does not cover products that is defective (or shall become defective) due to: (a) alteration of the products (or any part
thereof) by anyone other than Crow; (b) accident, abuse, negligence, or improper maintenance; (c) failure caused by a product which Crow did not provide; (d) failure
caused by software or hardware which Crow did not provide; (e) use or storage other than in accordance with Crow's specified operating and storage instructions.
There are no warranties, expressed or implied, of merchantability or fitness of the products for a particular purpose or otherwise, which extend beyond the description on
the face hereof.
This limited Warranty Certificate is the Purchaser's sole and exclusive remedy against Crow and Crow's sole and exclusive liability toward the Purchaser in connection
with the products, including without limitation - for defects or malfunctions of the products. This Warranty Certificate replaces all other warranties and liabilities, whether
oral, written, (non-mandatory) statutory, contractual, in tort or otherwise.
In no case shall Crow be liable to anyone for any consequential or incidental damages (inclusive of loss of profit, and whether occasioned by negligence of the Crow or
any third party on its behalf) for breach of this or any other warranty, expressed or implied, or upon any other basis of liability whatsoever. Crow does not represent that
these products can not be compromised or circumvented; that these products will prevent any person injury or property loss or damage by burglary, robbery, fire or
otherwise; or that these products will in all cases provide adequate warning or protection.
Purchaser understands that a properly installed and maintained product may in some cases reduce the risk of burglary, fire, robbery or other events occurring without
providing an alarm, but it is not insurance or a guarantee that such will not occur or that there will be no personal injury or property loss or damage as a result.
Consequently, Crow shall have no liability for any personal injury; property damage or any other loss based on claim that these products failed to give any warning.
If Crow is held liable, whether directly or indirectly, for any loss or damage with regards to these products, regardless of cause or origin, Crow's maximum liability shall not
in any case exceed the purchase price of these products, which shall be the complete and exclusive remedy against Crow.
P/N 7101572 REV. A Y.S - A.Y.
AJUSTE DE ALCANCE
"MW" POTENCIOMETRO– ajusta el alcance
del área a proteger- vea fig.5.
El potenciómetro a media escala es equivalente a
15m de distancia, a escala mínima- 7m.
Gire el potenciómetro en el sentido de las agujas del
reloj para incrementar el alcance, en sentido inverso
para reducir el alcance.
Las dimensiones cambian de acuerdo a la
localización y el tamaño de la habitación.
"PIR" POTENCIOMETRO– ajusta el alcance
del área a proteger.
Use el potenciómetro marcado"PIR" para ajustar la
sensibilidad de detección entre un 15% y un 100% de
acuerdo al test de andado en el area protegida.
(De fabrica es 57%)
Gire el potenciómetro en el sentido de las agujas del
reloj para incrementar el alcance, en sentido inverso
para reducir el alcance
Después de ajustar la sensibilidad, realice un test
de andado para verificar la correcta sensibilidad
para proteger el área.
BLOCK
CONNECTOR
ANTENNA
DOPPLER
TAMPER
MW
SENSITIVITY
ADJUSTMENT
SWITCH
FOR
PYROSENSOR
SETTINGS
Fig. 6
Soporte montaje techo
Fig.7
- 2 -
INSTRUCIONES DE INSTALACION
TECHNICAL SPECIFICATION
Método de detección
Alimentación
Consumo
Standby: 16.5 mA
Temperatura
Compensación
Periodo de alarma
Salida de alarma
Tamper
Periodo de espera
LED Indicación
mientras
Dimensiones
38mm
Peso
PIR
SENSITIVITY
ADJUSTMENT
Soporte pared
CROW ELECTRONIC ENGINEERING LTD.
ISRAEL:
USA:
AUSTRALIA:
SPAIN:
LATIN AMERICA:
ITALY:
These instructions supersede all previous issues in circulation prior to October 2004.
Cuatro elementos PIR &
microondas pulsos Doppler
8.2 a 16 Vdc
Activo :
25.5 mA
SI
2 +/- 1 sec
N.C 28Vdc 0.1 A con
10 Ohm resistencia de
protección
N.C 28Vdc 0.1A con
10 Ohm resistencia de
Protección. Activación por
Apertura.
1 min
Amarillo LED esta
Esta parpadeando
dura el periodo de
Encendido y el test
ROJO LED: ON mientras
Dura la alarma
Verde LED: PIR
Amarillo LED: MW
123mm x 62mm x
120gr
N345
57 Hamelacha St., Holon 58855
Tel: 972-3-5569937 /8 /9
Fax: 972-3-5592981
E-mail:
support@crow.co.il
2160 North Central Road,
Fort Lee, N.J. 07024
Tel: 1-800-GET CROW
or
(201) 944 0005
Fax: (201) 944 1199
E-mail:
support@crowelec.com
429 Nepean HWY Brighton East Vic 3187
Tel: 61-3-9596 7222
Fax: 61-3-9596 0888
E-mail:
crow@crowaust.com.au
by Demes, S.L..
San Fructuoso, 50-56.
08004-Barcelona España
Tel: (34) 934 254 960
Fax: (34) 934 261 904
E-mail: bydemes@bydemes.com
CROW LATIN AMERICA
ST
5753 NW 151
.Street
MIAMI LAKES,
FL 33014 – USA
Tel: +1-305-823-8700
Fax: +1-305-823-8711
E-mail:
sales@crowlatinamerica.com
DEATRONIC
VIA Giulianello 4/14
00178 ROMA, ITALY
Tel: +39-0676-12912
Fax: +39-0676-12601
E-mail:
info@deatronic.com

Publicidad

loading