OPERATION
3. Carefully install batteries into compartment and
arrange battery posts as shown (Figure 4).
FRONT
ATTENTION: Do not drop batteries into
compartment, battery and machine housing
damage may result. This damage in not covered
by warranty.
4. Connect cables to battery posts in numerical order
as labeled (RED TO POSITIVE & BLACK TO
NEGATIVE). (Figure 4)
5. Double check cable connections before closing up
battery compartment.
6. Reset the "MAIN" circuit breaker button.
7. Turn "MAIN" switch on, and check battery meter
charge level to ensure batteries are fully charged.
If batteries need charging, see BATTERY
CHARGING.

MACHINE SETUP

PRE–OPERATION CHECKS
1. Sweep and dust mop floor to remove particles and
other debris.
2. Check battery meter charge level to ensure
batteries are fully charged. (See BATTERY
CHARGING)
3. Check that pads or brushes are installed.
4. Check that squeegee is installed.
6
FIG. 4

INSTALLING BRUSH OR PAD DRIVERS

1. Turn Main switch to the "OFF" position and pull
out the Main Power circuit breaker button.
FOR SAFETY: Before leaving or servicing
machine, stop on level surface and turn off
machine.
ATTENTION: To prevent accidental starting, pull
out the Main Power circuit breaker button before
installing brush or pad drivers. Circuit breaker
button is located a rear of control housing.
2. Raise scrub head. Step down firmly on bottom
brush lift foot pedal to raise (Figure 5).
3. Unfasten black latch at front of machine and hinge
open skirt housing to access motor hub (Figure 6).
4. Select recommended pad or brush that best
meets your cleaning needs.
NOTE: Consult your authorized distributor for
pad/brush recommendations.
FIG. 5