LUBRICATION
Ingersoll–Rand No. 50
Always use an air line lubricator with these tools.
We recommend the following Filter–Lubricator–Regulator
Unit:
For USA – No. C31–06–G00
For Model 2934P2
Before starting the tool and after each eight hours of
operation, unless the air line lubricator is used, unscrew the
Oil Chamber Plug and fill the chamber with Ingersoll–Rand
No. 50 Oil.
After each forty–eight hours of operation, or as experience
indicates, inject about 3 cc of Ingersoll–Rand No. 100 Grease
(approximately 14 strokes from the No. R000A2–228 Grease
Gun) into the Grease Fitting.
For Model 2940P2
Before starting the tool and after each two or three hours
of operation, unless the air line lubricator is used, detach the
air hose an inject about 3 cc of Ingersoll–Rand No. 50 Oil into
the air inlet.
Model
2934P2
2940P2
PLACING TOOL IN SERVICE
Ingersoll–Rand No. 100
HOW TO ORDER AN IMPACTOOL
PISTOL GRIP WITH 1" SQUARE DRIVE
Impacts/min.
825
810
After each twenty hours of operation, or as experience
indicates, inject about 6 cc of Ingersoll–Rand No. 100 Grease
(approximately 14 strokes from the No. R000A2–228 Grease
Gun) into the Grease Fitting.
MAIN LINES 3 TIMES
AIR TOOL INLET SIZE
TO
AIR
SYSTEM
TO
AIR
TOOL
LUBRICATOR
REGULATOR
BRANCH LINE 2 TIMES
AIR TOOL INLET SIZE
DRAIN REGULARLY
Recommended Torque Range
ft–lb
500 – 1,100
1,000 – 1,600
3
FILTER
COMPRESSOR
(Dwg. TPD905–1)
Nm
678 – 1,490
1,360 – 2,170