Problem
Using a low fluid pressure
setting, the fluid flow is
too high, making it
necessary to restrict
needle travel to reduce
fluid flow.
Fluid system will not
operate at low enough
pressure [below 10 psi
(70 kPa, 0.7 bar)].

Technical Data

Maximum Fluid Inlet Pressure . . . . . . . . . . . . . . . . . . 300 psi (2.1 MPa, 21 bar)
Maximum Air Inlet Pressure . . . . . . . . . . . . . . . . . . . . 100 psi (0.7 MPa, 7 bar)
Maximum HVLP*/Compliant Inbound Air Pressure. . Printed on air cap. See Models, page 2.
Air Consumption
HVLP. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14.4 cfm at 29 psi (0.2 MPa, 2.0 bar)
Conventional . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13.3 cfm at 43 psi (0.3 MPa, 3.0 bar)
Compliant . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11.2 cfm at 35 psi (0.24 MPa, 2.4 bar)
Fluid and Air Opening Temperature Range . . . . . . . . 32°F to 109°F (0°C to 43°C)
Spray Gun:
Air Inlet . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1/4 npsm (R1/4-19)
Fluid Inlet . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3/8 npsm (R3/8-19)
Weight
Models 289232-289233. . . . . . . . . . . . . . . . . . . . 462 g (18.5 oz)
Models 24A525-24A533 . . . . . . . . . . . . . . . . . . . 410 g (16.4 oz)
Sound Data:
Conventional
Sound power at 43 psi (0.30 MPa, 3.0 bar). . . . . . . . 88.0 dB(A)**
Sound pressure at 43 psi (0.30 MPa, 3.0 bar). . . . . . 79.5 dB(A)**
HVLP
Sound power at 19 psi (0.13 MPa, 1.3 bar). . . . . . . . 89.7 dB(A)**
Sound pressure at 19 psi (0.13 MPa, 1.3 bar). . . . . . 79.8 dB(A)**
Compliant
Sound power at 29 psi (0.20 MPa, 2.0 bar). . . . . . . . 87.5 dB(A)**
Sound Power at 29 psi (0.20 MPa, 2.0 bar). . . . . . . . 77.5 dB(A)**
Pressure Cup Size (289233 only) . . . . . . . . . . . . . . . . 1 qt. (0.95 liter)
Wetted Parts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 303 SST, 17-4 PH SST, PEEK, acetal,
Produces 10 psi (0.07 MPa, 0.7 bar) spraying pressure at air cap.
*
All readings were taken with the fan valve fully open (fan full size) at the assumed operator
**
position. Sound power was tested per ISO 9614-2.
312412B
Cause
Using needle/nozzle kit
with too large orifice.
There is no fluid
regulator, or air regulator
is not sensitive enough
at low pressure.
Solution
Use needle/nozzle kit with smaller orifice.
Add low pressure fluid regulator, or add more
sensitive low pressure air regulator.